(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Examples.SimpleEngine_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Examples_SimpleEngine_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=25 --stepSize=0.025 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Examples_SimpleEngine_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Examples.SimpleEngine (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 25.000000 - tolerance : 1e-06 - stepSize : 0.025 warning: [fmi2Warning] SimpleEngine/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((conductionElement.p_min >= 611.657 and conductionElement.p_min <= 1e8), conductionElement.p_min=100) --> "Variable violating min/max constraint: 611.657 <= conductionElement.p_min <= 1e8, has value: 100" warning: [fmi2Warning] SimpleEngine/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((switchConnector.checkValve.p_min >= 611.657 and switchConnector.checkValve.p_min <= 1e8), switchConnector.checkValve.p_min=100) --> "Variable violating min/max constraint: 611.657 <= switchConnector.checkValve.p_min <= 1e8, has value: 100" warning: [fmi2Warning] SimpleEngine/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((switchConnector.checkValve1.p_min >= 611.657 and switchConnector.checkValve1.p_min <= 1e8), switchConnector.checkValve1.p_min=100) --> "Variable violating min/max constraint: 611.657 <= switchConnector.checkValve1.p_min <= 1e8, has value: 100" warning: [fmi2Warning] SimpleEngine/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((switchConnector1.checkValve.p_min >= 611.657 and switchConnector1.checkValve.p_min <= 1e8), switchConnector1.checkValve.p_min=100) --> "Variable violating min/max constraint: 611.657 <= switchConnector1.checkValve.p_min <= 1e8, has value: 100" warning: [fmi2Warning] SimpleEngine/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((switchConnector1.checkValve1.p_min >= 611.657 and switchConnector1.checkValve1.p_min <= 1e8), switchConnector1.checkValve1.p_min=100) --> "Variable violating min/max constraint: 611.657 <= switchConnector1.checkValve1.p_min <= 1e8, has value: 100" warning: [fmi2Warning] SimpleEngine/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((switch.tanValve.p_min >= 611.657 and switch.tanValve.p_min <= 1e8), switch.tanValve.p_min=100) --> "Variable violating min/max constraint: 611.657 <= switch.tanValve.p_min <= 1e8, has value: 100" warning: [fmi2Warning] SimpleEngine/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((switch.tanValve1.p_min >= 611.657 and switch.tanValve1.p_min <= 1e8), switch.tanValve1.p_min=100) --> "Variable violating min/max constraint: 611.657 <= switch.tanValve1.p_min <= 1e8, has value: 100" warning: [fmi2Warning] SimpleEngine/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((flowResistance3.p_min >= 611.657 and flowResistance3.p_min <= 1e8), flowResistance3.p_min=100) --> "Variable violating min/max constraint: 611.657 <= flowResistance3.p_min <= 1e8, has value: 100" warning: [fmi2Warning] SimpleEngine/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((flowResistance4.p_min >= 611.657 and flowResistance4.p_min <= 1e8), flowResistance4.p_min=100) --> "Variable violating min/max constraint: 611.657 <= flowResistance4.p_min <= 1e8, has value: 100" warning: [fmi2Warning] SimpleEngine/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((flowResistance5.p_min >= 611.657 and flowResistance5.p_min <= 1e8), flowResistance5.p_min=100) --> "Variable violating min/max constraint: 611.657 <= flowResistance5.p_min <= 1e8, has value: 100" warning: [fmi2Warning] SimpleEngine/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((flowResistance6.p_min >= 611.657 and flowResistance6.p_min <= 1e8), flowResistance6.p_min=100) --> "Variable violating min/max constraint: 611.657 <= flowResistance6.p_min <= 1e8, has value: 100" warning: [fmi2Warning] SimpleEngine/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((tanValve.p_min >= 611.657 and tanValve.p_min <= 1e8), tanValve.p_min=100) --> "Variable violating min/max constraint: 611.657 <= tanValve.p_min <= 1e8, has value: 100" warning: [fmi2Warning] SimpleEngine/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((tanValve1.p_min >= 611.657 and tanValve1.p_min <= 1e8), tanValve1.p_min=100) --> "Variable violating min/max constraint: 611.657 <= tanValve1.p_min <= 1e8, has value: 100" info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Examples.SimpleEngine_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable SimpleEngine.boiler.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.conductionElement.conductionString will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.conductionElement.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.conductionElement.parameterString will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.flowResistance3.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.flowResistance4.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.flowResistance5.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.flowResistance6.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.junctionT2_1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.junctionT2_1.junctionN.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.singleSensorSelect.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.singleSensorSelect.quantityString will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.steamSink.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.steamSink.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.steamSink.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switch.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switch.splitterT2_1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switch.splitterT2_1.splitterN.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switch.tanValve.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switch.tanValve1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector.checkValve.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector.checkValve1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector.connectInletFore.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector.connectRearOutlet.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector.junctionRFF2_1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector.junctionRFF2_1.junctionMN.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector.sensorState.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector1.checkValve.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector1.checkValve1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector1.connectInletFore.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector1.connectRearOutlet.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector1.junctionRFF2_1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector1.junctionRFF2_1.junctionMN.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.switchConnector1.sensorState.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.tanValve.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.tanValve1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable SimpleEngine.terminalSource.instanceName will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] SimpleEngine/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Water/IF97_Utilities.mo:6796: Error in region computation of IF97 steam tables(p = 400000, h = 2.27136e+07) error: [stepUntil] fmi2_doStep failed for FMU "SimpleEngine.root.SimpleEngine" error: [fmi2logger] [fmi2Error] SimpleEngine/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Water/IF97_Utilities.mo:6796: Error in region computation of IF97 steam tables(p = 400000, h = 2.27136e+07) error: [fmi2logger] [fmi2Error] SimpleEngine/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable booleanToReal.u Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 13 warnings info: 5 errors