(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_TAeZoSysPro_TAeZoSysPro_FluidDynamics_Examples_Pressure_coocker_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=3600 --stepSize=7.2 --mode=cs --timeout=240 --tolerance=1e-06 ../TAeZoSysPro_TAeZoSysPro_FluidDynamics_Examples_Pressure_coocker_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : TAeZoSysPro.FluidDynamics.Examples.Pressure_coocker (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 3600.000000 - tolerance : 1e-06 - stepSize : 7.2 warning: [fmi2Warning] Pressure_coocker/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro 3.3.0-master/HeatTransfer/Functions/FreeConvection/vertical_plate_ASHRAE.mo:20: the Rayleigh number < 10^9 is out of the range of the correlation. => Correlation extrapolated warning: [fmi2Warning] Pressure_coocker/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro 3.3.0-master/HeatTransfer/Functions/FreeConvection/ground_ASHRAE.mo:57: the Rayleigh number <10^5 is out of the range of the correlation info: Result file: TAeZoSysPro_TAeZoSysPro_FluidDynamics_Examples_Pressure_coocker_OMSimulator-cs-euler_res.mat (bufferSize=10) LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro 3.3.0-master/FluidDynamics/Components/Orifices/Opening.mo:121:3-121:148:writable] | | | | The following assertion has been violated at time 21.600000 | | | | ((simpleOpening.M <= 0.3), simpleOpening.M=0.5791799919427446) --> "Mach number > 0.3, the flow becomes compressible. The assumption of uncrompressible flow is not valid" error: [fmi2logger] [fmi2Error] Pressure_coocker/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Media/Water/IF97_Utilities.mo:2897: IF97 medium function tsat called with too low pressure p = -11045.5 Pa <= 611.657 Pa (triple point pressure) error: [stepUntil] fmi2_doStep failed for FMU "Pressure_coocker.root.Pressure_coocker" error: [fmi2logger] [fmi2Error] Pressure_coocker/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Media/Water/IF97_Utilities.mo:2897: IF97 medium function tsat called with too low pressure p = -11045.5 Pa <= 611.657 Pa (triple point pressure) error: [fmi2logger] [fmi2Error] Pressure_coocker/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable liquidNode.medium.standardOrderComponents Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 2 warnings info: 5 errors