(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../PowerGrids_dev_PowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridWithPSS_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_PowerGrids_dev_PowerGrids_Examples_Tutorial_GridOperation_Controlled_ControlledGridWithPSS_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=10 --stepSize=0.02 --mode=cs --timeout=240 --tolerance=1e-06 ../PowerGrids_dev_PowerGrids_Examples_Tutorial_GridOperation_Controlled_ControlledGridWithPSS_OMSimulator-cs-euler.fmu) LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. info: *** FMU Simulation Info *** - model : PowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridWithPSS (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 10.000000 - tolerance : 1e-06 - stepSize : 0.02 info: Result file: ../PowerGrids_dev_PowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridWithPSS_OMSimulator-cs-euler_res.mat (bufferSize=10) LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GEN.VPuCheck > GEN.VPuMin), GEN.VPuCheck=0.4096172948004524, GEN.VPuMin=0.7) --> "Voltage too low (VPu=0.409617 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GEN.IPuCheck < GEN.IPuMax), GEN.IPuCheck=2.561538534803955, GEN.IPuMax=2.5) --> "Current too high (IPu=2.56154 > 2.5), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((NTLV.VPuCheck > NTLV.VPuMin), NTLV.VPuCheck=0.4096172948004524, NTLV.VPuMin=0.7) --> "Voltage too low (VPu=0.409617 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GRID.VPuCheck > GRID.VPuMin), GRID.VPuCheck=0.001211586289821356, GRID.VPuMin=0.7) --> "Voltage too low (VPu=0.00121159 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GRID.IPuCheck < GRID.IPuMax), GRID.IPuCheck=4.772519510853477, GRID.IPuMax=2.5) --> "Current too high (IPu=4.77252 > 2.5), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GRIDL.VPuCheck > GRIDL.VPuMin), GRIDL.VPuCheck=0.001211586289821356, GRIDL.VPuMin=0.7) --> "Voltage too low (VPu=0.00121159 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((FAULT.VPuCheck > FAULT.VPuMin), FAULT.VPuCheck=0.001211586289821356, FAULT.VPuMin=0.7) --> "Voltage too low (VPu=0.00121159 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((FAULT.IPuCheck < FAULT.IPuMax), FAULT.IPuCheck=6.998122410012411, FAULT.IPuMax=2.5) --> "Current too high (IPu=6.99812 > 2.5), check if the numerical solution is valid"