(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_PowerGrids_dev_PowerGrids_Examples_IEEE14bus_IEEE14busShort4_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=4 --stepSize=0.008 --mode=cs --timeout=240 --tolerance=1e-06 ../PowerGrids_dev_PowerGrids_Examples_IEEE14bus_IEEE14busShort4_OMSimulator-cs-euler.fmu) LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. info: *** FMU Simulation Info *** - model : PowerGrids.Examples.IEEE14bus.IEEE14busShort4 (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 4.000000 - tolerance : 1e-06 - stepSize : 0.008 info: Result file: PowerGrids_dev_PowerGrids_Examples_IEEE14bus_IEEE14busShort4_OMSimulator-cs-euler_res.mat (bufferSize=10) LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((bus4.VPuCheck > bus4.VPuMin), bus4.VPuCheck=0.000189702251283693, bus4.VPuMin=0.7) --> "Voltage too low (VPu=0.000189702 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((bus5.VPuCheck > bus5.VPuMin), bus5.VPuCheck=0.3068155773309941, bus5.VPuMin=0.7) --> "Voltage too low (VPu=0.306816 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((bus6.VPuCheck > bus6.VPuMin), bus6.VPuCheck=0.6708719544688775, bus6.VPuMin=0.7) --> "Voltage too low (VPu=0.670872 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((bus7.VPuCheck > bus7.VPuMin), bus7.VPuCheck=0.4293645148587725, bus7.VPuMin=0.7) --> "Voltage too low (VPu=0.429365 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((bus9.VPuCheck > bus9.VPuMin), bus9.VPuCheck=0.4264713950571113, bus9.VPuMin=0.7) --> "Voltage too low (VPu=0.426471 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((bus10.VPuCheck > bus10.VPuMin), bus10.VPuCheck=0.4657774450108275, bus10.VPuMin=0.7) --> "Voltage too low (VPu=0.465777 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((bus11.VPuCheck > bus11.VPuMin), bus11.VPuCheck=0.5639517145024412, bus11.VPuMin=0.7) --> "Voltage too low (VPu=0.563952 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((bus12.VPuCheck > bus12.VPuMin), bus12.VPuCheck=0.6443698187632476, bus12.VPuMin=0.7) --> "Voltage too low (VPu=0.64437 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((bus13.VPuCheck > bus13.VPuMin), bus13.VPuCheck=0.6246948598970548, bus13.VPuMin=0.7) --> "Voltage too low (VPu=0.624695 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((bus14.VPuCheck > bus14.VPuMin), bus14.VPuCheck=0.5027032981099429, bus14.VPuMin=0.7) --> "Voltage too low (VPu=0.502703 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((Load4.VPuCheck > Load4.VPuMin), Load4.VPuCheck=0.0001897022512840842, Load4.VPuMin=0.7) --> "Voltage too low (VPu=0.000189702 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((Load5.VPuCheck > Load5.VPuMin), Load5.VPuCheck=0.3068155773309942, Load5.VPuMin=0.7) --> "Voltage too low (VPu=0.306816 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((Load6.VPuCheck > Load6.VPuMin), Load6.VPuCheck=0.6708719544688775, Load6.VPuMin=0.7) --> "Voltage too low (VPu=0.670872 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((Load9.VPuCheck > Load9.VPuMin), Load9.VPuCheck=0.4264713950571113, Load9.VPuMin=0.7) --> "Voltage too low (VPu=0.426471 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((Load10.VPuCheck > Load10.VPuMin), Load10.VPuCheck=0.4657774450108275, Load10.VPuMin=0.7) --> "Voltage too low (VPu=0.465777 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((Load11.VPuCheck > Load11.VPuMin), Load11.VPuCheck=0.5639517145024412, Load11.VPuMin=0.7) --> "Voltage too low (VPu=0.563952 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((Load12.VPuCheck > Load12.VPuMin), Load12.VPuCheck=0.6443698187632478, Load12.VPuMin=0.7) --> "Voltage too low (VPu=0.64437 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((Load13.VPuCheck > Load13.VPuMin), Load13.VPuCheck=0.624694859897055, Load13.VPuMin=0.7) --> "Voltage too low (VPu=0.624695 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((Load14.VPuCheck > Load14.VPuMin), Load14.VPuCheck=0.5027032981099429, Load14.VPuMin=0.7) --> "Voltage too low (VPu=0.502703 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((Cbank9.VPuCheck > Cbank9.VPuMin), Cbank9.VPuCheck=0.4264713950571113, Cbank9.VPuMin=0.7) --> "Voltage too low (VPu=0.426471 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((GEN6.GEN.VPu > GEN6.GEN.VPuMin), GEN6.GEN.VPu=0.6708719544688775, GEN6.GEN.VPuMin=0.7) --> "Voltage too low (VPu=0.670872 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((GEN6.GEN.IPuCheck < GEN6.GEN.IPuMax), GEN6.GEN.IPuCheck=2.767782630695745, GEN6.GEN.IPuMax=2.5) --> "Current too high (IPu=2.76778 > 2.5), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((FAULT4.VPuCheck > FAULT4.VPuMin), FAULT4.VPuCheck=0.000189702251283693, FAULT4.VPuMin=0.7) --> "Voltage too low (VPu=0.000189702 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((FAULT4.IPuCheck < FAULT4.IPuMax), FAULT4.IPuCheck=18.97022512836952, FAULT4.IPuMax=2.5) --> "Current too high (IPu=18.9702 > 2.5), check if the numerical solution is valid"