(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../PowerGrids_dev_PowerGrids.Electrical.Test.TwoBusesResistiveTransmissionLineFault_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_PowerGrids_dev_PowerGrids_Electrical_Test_TwoBusesResistiveTransmissionLineFault_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=1 --stepSize=0.02 --mode=cs --timeout=240 --tolerance=1e-06 ../PowerGrids_dev_PowerGrids_Electrical_Test_TwoBusesResistiveTransmissionLineFault_OMSimulator-cs-euler.fmu) LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. info: *** FMU Simulation Info *** - model : PowerGrids.Electrical.Test.TwoBusesResistiveTransmissionLineFault (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1.000000 - tolerance : 1e-06 - stepSize : 0.02 info: Result file: ../PowerGrids_dev_PowerGrids.Electrical.Test.TwoBusesResistiveTransmissionLineFault_OMSimulator-cs-euler_res.mat (bufferSize=10) LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated at time 0.400000 | | | | ((infiniteBusA.IPuCheck < infiniteBusA.IPuMax), infiniteBusA.IPuCheck=5.411255411255571, infiniteBusA.IPuMax=2.5) --> "Current too high (IPu=5.41126 > 2.5), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 0.400000 | | | | ((transmissionLine.threePhaseFault.VPuCheck > transmissionLine.threePhaseFault.VPuMin), transmissionLine.threePhaseFault.VPuCheck=0.4696969696969519, transmissionLine.threePhaseFault.VPuMin=0.7) --> "Voltage too low (VPu=0.469697 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated at time 0.400000 | | | | ((transmissionLine.threePhaseFault.IPuCheck < transmissionLine.threePhaseFault.IPuMax), transmissionLine.threePhaseFault.IPuCheck=15.65656565656476, transmissionLine.threePhaseFault.IPuMax=2.5) --> "Current too high (IPu=15.6566 > 2.5), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 0.400000 | | | | ((transmissionLine.busFault.VPuCheck > transmissionLine.busFault.VPuMin), transmissionLine.busFault.VPuCheck=0.4696969696969519, transmissionLine.busFault.VPuMin=0.7) --> "Voltage too low (VPu=0.469697 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated at time 0.400000 | | | | ((infiniteBusB.IPuCheck < infiniteBusB.IPuMax), infiniteBusB.IPuCheck=9.220779220778272, infiniteBusB.IPuMax=2.5) --> "Current too high (IPu=9.22078 > 2.5), check if the numerical solution is valid"