(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=10 --stepSize=0.004 --mode=cs --timeout=240 --tolerance=1e-08 ../OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : OpenHydraulics.DevelopmentTests.DirectionalValveTest (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 10.000000 - tolerance : 1e-08 - stepSize : 0.004 info: Result file: OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable DirectionalValveTest.oil.oilName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.A2T.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.A2T.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.A2T.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.B2T.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.B2T.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.B2T.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2A.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2A.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2A.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2B.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2B.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2B.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] DirectionalValveTest/logStatusError: Model error: Argument of sqrt(x) was -28145.1 should be >= 0 error: [fmi2logger] [fmi2Error] DirectionalValveTest/logFmi2Call: fmi2DoStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "DirectionalValveTest.root.DirectionalValveTest" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 3 errors