(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Modelica_trunk_Modelica.Fluid.Examples.HeatingSystem_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Modelica_trunk_Modelica_Fluid_Examples_HeatingSystem_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=6000 --stepSize=1.19904 --mode=cs --timeout=240 --tolerance=1e-06 ../Modelica_trunk_Modelica_Fluid_Examples_HeatingSystem_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Modelica.Fluid.Examples.HeatingSystem (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 6000.000000 - tolerance : 1e-06 - stepSize : 1.19904 info: Result file: ../Modelica_trunk_Modelica.Fluid.Examples.HeatingSystem_OMSimulator-cs-euler_res.mat (bufferSize=10) LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Media/package.mo:4055:7-4056:76:writable] | | | | The following assertion has been violated at time 3.597120 | | | | ((pipe.mediums[2].p >= 0.0), pipe.mediums[2].p=-6461291.206209301) --> "Pressure (= -6.46129e+06 Pa) of medium "Liquid linear water" is negative | | | | (Temperature = 344.657 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Media/package.mo:4055:7-4056:76:writable] | | | | The following assertion has been violated at time 3.597120 | | | | ((heater.mediums[1].p >= 0.0), heater.mediums[1].p=-726778203.0273733) --> "Pressure (= -7.26778e+08 Pa) of medium "Liquid linear water" is negative | | | | (Temperature = 329.841 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Fluid/Interfaces.mo:344:3-344:118:writable] | | | | The following assertion has been violated at time 3.597120 | | | | ((radiator.m_flows[1] > (-valve.m_flow_small)), radiator.m_flows[1]=-0.02525990938305726, valve.m_flow_small=0.0001) --> "Reversing flow occurs even though allowFlowReversal is false" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Fluid/Interfaces.mo:344:3-344:118:writable] | | | | The following assertion has been violated at time 3.597120 | | | | ((radiator.m_flows[1] > (-valve.m_flow_small)), radiator.m_flows[1]=-0.02525990938305726, valve.m_flow_small=0.0001) --> "Reversing flow occurs even though allowFlowReversal is false" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Media/package.mo:4055:7-4056:76:writable] | | | | The following assertion has been violated at time 3.597120 | | | | ((heater.mediums[1].p >= 0.0), heater.mediums[1].p=-726778203.0273733) --> "Pressure (= -7.26778e+08 Pa) of medium "Liquid linear water" is negative | | | | (Temperature = 329.841 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Media/package.mo:4055:7-4056:76:writable] | | | | The following assertion has been violated at time 3.597120 | | | | ((pipe.mediums[2].p >= 0.0), pipe.mediums[2].p=-6461291.206209301) --> "Pressure (= -6.46129e+06 Pa) of medium "Liquid linear water" is negative | | | | (Temperature = 344.657 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Fluid/Interfaces.mo:344:3-344:118:writable] | | | | The following assertion has been violated at time 3.597120 | | | | ((radiator.m_flows[1] > (-valve.m_flow_small)), radiator.m_flows[1]=-0.02525990938305726, valve.m_flow_small=0.0001) --> "Reversing flow occurs even though allowFlowReversal is false" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Media/package.mo:4055:7-4056:76:writable] | | | | The following assertion has been violated at time 3.597120 | | | | ((heater.mediums[1].p >= 0.0), heater.mediums[1].p=-726778203.0273733) --> "Pressure (= -7.26778e+08 Pa) of medium "Liquid linear water" is negative | | | | (Temperature = 329.841 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Media/package.mo:4055:7-4056:76:writable] | | | | The following assertion has been violated at time 3.597120 | | | | ((pipe.mediums[2].p >= 0.0), pipe.mediums[2].p=-6461291.206209301) --> "Pressure (= -6.46129e+06 Pa) of medium "Liquid linear water" is negative | | | | (Temperature = 344.657 K)" LOG_ASSERT | error | No event found, but assert was triggered. Throwing now! error: [fmi2logger] [fmi2Error] HeatingSystem/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Media/package.mo:4055: The following assertion has been violated at time 3.597120 ((pipe.mediums[2].p >= 0.0), pipe.mediums[2].p=-6461291.206209301) --> "Pressure (= -6.46129e+06 Pa) of medium "Liquid linear water" is negative (Temperature = 344.657 K)" error: [fmi2logger] [fmi2Error] HeatingSystem/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "HeatingSystem.root.HeatingSystem" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Media/package.mo:4055:7-4056:76:writable] | | | | The following assertion has been violated at time 3.597120 | | | | ((pipe.mediums[2].p >= 0.0), pipe.mediums[2].p=-6461291.206209301) --> "Pressure (= -6.46129e+06 Pa) of medium "Liquid linear water" is negative | | | | (Temperature = 344.657 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Media/package.mo:4055:7-4056:76:writable] | | | | The following assertion has been violated at time 3.597120 | | | | ((heater.mediums[1].p >= 0.0), heater.mediums[1].p=-726778203.0273733) --> "Pressure (= -7.26778e+08 Pa) of medium "Liquid linear water" is negative | | | | (Temperature = 329.841 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Fluid/Interfaces.mo:344:3-344:118:writable] | | | | The following assertion has been violated at time 3.597120 | | | | ((radiator.m_flows[1] > (-valve.m_flow_small)), radiator.m_flows[1]=-0.02525990938305726, valve.m_flow_small=0.0001) --> "Reversing flow occurs even though allowFlowReversal is false" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 3 errors