(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Dynawo_dev_Dynawo.Examples.SVarC.SVarCStepURef_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Dynawo_dev_Dynawo_Examples_SVarC_SVarCStepURef_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=3 --stepSize=0.006 --mode=cs --timeout=240 --tolerance=1e-06 ../Dynawo_dev_Dynawo_Examples_SVarC_SVarCStepURef_OMSimulator-cs-euler.fmu) warning: [SVarCStepURef: resources/0001_SVarCStepURef.fmu] The FMU lists 114 initial unknowns and exposes 114 initial unknowns. * 57: infiniteBus.UPuVar is missing * 68: sVarCStandard.GPuCst.k is missing * 69: sVarCStandard.GPuCst.y is missing * 76: sVarCStandard.PuConversion.k is missing * 82: sVarCStandard.UBlockPu is missing * 102: sVarCStandard.calculationBG.BShuntPu is missing * 103: sVarCStandard.calculationBG.GCstPu is missing * 136: sVarCStandard.regulation.SNom is missing * 137: sVarCStandard.regulation.Ti is missing * 142: sVarCStandard.regulation.add3.k1 is missing * 152: sVarCStandard.regulation.limitations.IMinPu is missing * 153: sVarCStandard.regulation.limitations.KCurrentLimiter is missing * 156: sVarCStandard.regulation.limitations.add1.u1 is missing * 168: sVarCStandard.regulation.limitations.limIntegratorMax.k is missing * 171: sVarCStandard.regulation.limitations.limIntegratorMax.y_start is missing * 179: sVarCStandard.regulation.limitations.min2.u2 is missing * 182: sVarCStandard.regulation.zero.y is missing * 251: line.NbSwitchOffSignals is missing * 256: sVarCStandard.SetModeManual0 is missing * 263: sVarCStandard.regulation.limitations.limIntegratorMin.initType is missing * 264: sVarCStandard.setModeManual is missing * 274: line.Running0 is missing * 279: sVarCStandard.injector.Running0 is missing * 293: sVarCStandard.regulation.limitations.limIntegratorMin.use_set is missing * 296: selectMode.y is missing * 53: infiniteBus.UNom is wrongly listed * 64: sVarCStandard.BMinPu is wrongly listed * 67: sVarCStandard.G0Pu is wrongly listed * 74: sVarCStandard.Lambda is wrongly listed * 80: sVarCStandard.U0Pu is wrongly listed * 86: sVarCStandard.URefUp is wrongly listed * 93: sVarCStandard.UUnblockUp is wrongly listed * 104: sVarCStandard.i0Pu.im is wrongly listed * 105: sVarCStandard.i0Pu.re is wrongly listed * 140: sVarCStandard.regulation.add2.k1 is wrongly listed * 144: sVarCStandard.regulation.add4.k1 is wrongly listed * 145: sVarCStandard.regulation.add4.k2 is wrongly listed * 154: sVarCStandard.regulation.limitations.add1.k1 is wrongly listed * 157: sVarCStandard.regulation.limitations.add2.k1 is wrongly listed * 158: sVarCStandard.regulation.limitations.add2.k2 is wrongly listed * 170: sVarCStandard.regulation.limitations.limIntegratorMax.outMin is wrongly listed * 173: sVarCStandard.regulation.limitations.limIntegratorMin.outMax is wrongly listed * 249: sVarCStandard.modeHandling.modeAuto is wrongly listed * 252: line.State0 is wrongly listed * 255: sVarCStandard.Mode0 is wrongly listed * 258: sVarCStandard.injector.State0 is wrongly listed * 272: sVarCStandard.switchOffSignal2 is wrongly listed * 277: line.SwitchOffSignal30 is wrongly listed * 281: sVarCStandard.injector.SwitchOffSignal20 is wrongly listed * 282: sVarCStandard.injector.SwitchOffSignal30 is wrongly listed info: [SVarCStepURef: resources/0001_SVarCStepURef.fmu] The FMU contains bad initial unknowns. This might cause problems, e.g. wrong simulation results. LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. info: *** FMU Simulation Info *** - model : Dynawo.Examples.SVarC.SVarCStepURef (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 3.000000 - tolerance : 1e-06 - stepSize : 0.006 info: Result file: ../Dynawo_dev_Dynawo.Examples.SVarC.SVarCStepURef_OMSimulator-cs-euler_res.mat (bufferSize=10) info: 1 warnings info: 0 errors