(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Dynawo_dev_Dynawo.Examples.SVarC.SVarCLoadVarQLarge_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Dynawo_dev_Dynawo_Examples_SVarC_SVarCLoadVarQLarge_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=3 --stepSize=0.006 --mode=cs --timeout=240 --tolerance=1e-06 ../Dynawo_dev_Dynawo_Examples_SVarC_SVarCLoadVarQLarge_OMSimulator-cs-euler.fmu) warning: [SVarCLoadVarQLarge: resources/0001_SVarCLoadVarQLarge.fmu] The FMU lists 130 initial unknowns and exposes 130 initial unknowns. * 66: PRefPu.y is missing * 71: URef.y is missing * 76: infiniteBus.UPuVar is missing * 89: load_INIT.Q0Pu is missing * 90: load_INIT.U0Pu is missing * 98: sVarCStandard.GPuCst.k is missing * 99: sVarCStandard.GPuCst.y is missing * 106: sVarCStandard.PuConversion.k is missing * 114: sVarCStandard.URef is missing * 133: sVarCStandard.calculationBG.BShuntPu is missing * 134: sVarCStandard.calculationBG.GCstPu is missing * 168: sVarCStandard.regulation.SNom is missing * 169: sVarCStandard.regulation.Ti is missing * 174: sVarCStandard.regulation.add3.k1 is missing * 184: sVarCStandard.regulation.limitations.IMinPu is missing * 185: sVarCStandard.regulation.limitations.KCurrentLimiter is missing * 188: sVarCStandard.regulation.limitations.add1.u1 is missing * 200: sVarCStandard.regulation.limitations.limIntegratorMax.k is missing * 203: sVarCStandard.regulation.limitations.limIntegratorMax.y_start is missing * 211: sVarCStandard.regulation.limitations.min2.u2 is missing * 214: sVarCStandard.regulation.zero.y is missing * 284: loadPQ.NbSwitchOffSignals is missing * 289: sVarCStandard.SetModeManual0 is missing * 296: sVarCStandard.regulation.limitations.limIntegratorMin.initType is missing * 297: sVarCStandard.setModeManual is missing * 310: line.Running0 is missing * 314: loadPQ.Running0 is missing * 319: sVarCStandard.injector.Running0 is missing * 333: sVarCStandard.regulation.limitations.limIntegratorMin.use_set is missing * 336: selectMode.y is missing * 64: sVarCStandard.modeHandling.timerModeChangeUp is wrongly listed * 69: QRefPu.startTime is wrongly listed * 72: infiniteBus.UNom is wrongly listed * 79: line.RPu is wrongly listed * 80: line.XPu is wrongly listed * 94: sVarCStandard.BMinPu is wrongly listed * 97: sVarCStandard.G0Pu is wrongly listed * 104: sVarCStandard.Lambda is wrongly listed * 110: sVarCStandard.U0Pu is wrongly listed * 117: sVarCStandard.URefUp is wrongly listed * 124: sVarCStandard.UUnblockUp is wrongly listed * 135: sVarCStandard.i0Pu.im is wrongly listed * 136: sVarCStandard.i0Pu.re is wrongly listed * 172: sVarCStandard.regulation.add2.k1 is wrongly listed * 176: sVarCStandard.regulation.add4.k1 is wrongly listed * 177: sVarCStandard.regulation.add4.k2 is wrongly listed * 186: sVarCStandard.regulation.limitations.add1.k1 is wrongly listed * 189: sVarCStandard.regulation.limitations.add2.k1 is wrongly listed * 190: sVarCStandard.regulation.limitations.add2.k2 is wrongly listed * 202: sVarCStandard.regulation.limitations.limIntegratorMax.outMin is wrongly listed * 205: sVarCStandard.regulation.limitations.limIntegratorMin.outMax is wrongly listed * 280: sVarCStandard.modeHandling.modeAuto is wrongly listed * 285: loadPQ.State0 is wrongly listed * 288: sVarCStandard.Mode0 is wrongly listed * 291: sVarCStandard.injector.State0 is wrongly listed * 308: sVarCStandard.switchOffSignal2 is wrongly listed * 312: line.SwitchOffSignal20 is wrongly listed * 317: loadPQ.SwitchOffSignal30 is wrongly listed * 321: sVarCStandard.injector.SwitchOffSignal20 is wrongly listed * 322: sVarCStandard.injector.SwitchOffSignal30 is wrongly listed info: [SVarCLoadVarQLarge: resources/0001_SVarCLoadVarQLarge.fmu] The FMU contains bad initial unknowns. This might cause problems, e.g. wrong simulation results. LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. info: *** FMU Simulation Info *** - model : Dynawo.Examples.SVarC.SVarCLoadVarQLarge (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 3.000000 - tolerance : 1e-06 - stepSize : 0.006 info: Result file: ../Dynawo_dev_Dynawo.Examples.SVarC.SVarCLoadVarQLarge_OMSimulator-cs-euler_res.mat (bufferSize=10) info: 1 warnings info: 0 errors