(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ClaRa_dev_ClaRa.Components.Mills.HardCoalMills.Check.combineMillandFurnace_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ClaRa_dev_ClaRa_Components_Mills_HardCoalMills_Check_combineMillandFurnace_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=20000 --stepSize=8 --mode=cs --timeout=240 --tolerance=1e-06 ../ClaRa_dev_ClaRa_Components_Mills_HardCoalMills_Check_combineMillandFurnace_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ClaRa.Components.Mills.HardCoalMills.Check.combineMillandFurnace (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 20000.000000 - tolerance : 1e-06 - stepSize : 8 LOG_STDOUT | info | TILMedia-Error(combineMillandFurnace.mills1.gasIn, GM_GasMixtureModel_setState_pTxi, mediumPointerID=8): negative pressure (p=0.000000)! Stopping property calculation! LOG_STDOUT | info | TILMedia-Error(combineMillandFurnace.mills1.gasIn, GM_GasMixtureModel_setState_pTxi, mediumPointerID=8): negative pressure (p=0.000000)! Stopping property calculation! LOG_STDOUT | info | TILMedia-Error(combineMillandFurnace.mills1.gasIn, GM_GasMixtureModel_setState_pTxi, mediumPointerID=8): negative pressure (p=0.000000)! Stopping property calculation! LOG_STDOUT | info | TILMedia-Error(combineMillandFurnace.mills1.gasIn, GM_GasMixtureModel_setState_pTxi, mediumPointerID=8): negative pressure (p=0.000000)! Stopping property calculation! LOG_STDOUT | info | TILMedia-Error(combineMillandFurnace.mills1.gasIn, GM_GasMixtureModel_setState_pTxi, mediumPointerID=8): negative pressure (p=0.000000)! Stopping property calculation! LOG_STDOUT | info | TILMedia-Error(combineMillandFurnace.mills1.gasIn, GM_GasMixtureModel_setState_pTxi, mediumPointerID=8): negative pressure (p=0.000000)! Stopping property calculation! LOG_STDOUT | info | TILMedia-Error(combineMillandFurnace.mills1.gasIn, GM_GasMixtureModel_setState_pTxi, mediumPointerID=8): negative pressure (p=0.000000)! Stopping property calculation! LOG_STDOUT | info | TILMedia-Error(combineMillandFurnace.mills1.gasIn, GM_GasMixtureModel_setState_pTxi, mediumPointerID=8): negative pressure (p=0.000000)! Stopping property calculation! warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((mills1.gasIn.drhodxi_ph[2] >= 0.0), mills1.gasIn.drhodxi_ph[2]=-0.5534598295017348) --> "Variable violating min constraint: 0.0 <= mills1.gasIn.drhodxi_ph[2], has value: -0.55346" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((mills1.gasIn.drhodxi_ph[5] >= 0.0), mills1.gasIn.drhodxi_ph[5]=-0.5550362018686763) --> "Variable violating min constraint: 0.0 <= mills1.gasIn.drhodxi_ph[5], has value: -0.555036" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((mills1.gasIn.drhodxi_ph[6] >= 0.0), mills1.gasIn.drhodxi_ph[6]=-0.247050762972227) --> "Variable violating min constraint: 0.0 <= mills1.gasIn.drhodxi_ph[6], has value: -0.247051" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((mills1.gasIn.drhodxi_ph[8] >= 0.0), mills1.gasIn.drhodxi_ph[8]=-1.678489908731801) --> "Variable violating min constraint: 0.0 <= mills1.gasIn.drhodxi_ph[8], has value: -1.67849" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((mills1.gasIn.drhodxi_ph[9] >= 0.0), mills1.gasIn.drhodxi_ph[9]=-1.747443892809433) --> "Variable violating min constraint: 0.0 <= mills1.gasIn.drhodxi_ph[9], has value: -1.74744" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((mills1.gasOut.drhodxi_ph[2] >= 0.0), mills1.gasOut.drhodxi_ph[2]=-0.2034811045521269) --> "Variable violating min constraint: 0.0 <= mills1.gasOut.drhodxi_ph[2], has value: -0.203481" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((mills1.gasOut.drhodxi_ph[5] >= 0.0), mills1.gasOut.drhodxi_ph[5]=-0.2037394633509579) --> "Variable violating min constraint: 0.0 <= mills1.gasOut.drhodxi_ph[5], has value: -0.203739" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((mills1.gasOut.drhodxi_ph[6] >= 0.0), mills1.gasOut.drhodxi_ph[6]=-0.1014861662446173) --> "Variable violating min constraint: 0.0 <= mills1.gasOut.drhodxi_ph[6], has value: -0.101486" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((mills1.gasOut.drhodxi_ph[8] >= 0.0), mills1.gasOut.drhodxi_ph[8]=-0.6041561000342486) --> "Variable violating min constraint: 0.0 <= mills1.gasOut.drhodxi_ph[8], has value: -0.604156" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((mills1.gasOut.drhodxi_ph[9] >= 0.0), mills1.gasOut.drhodxi_ph[9]=-0.6457931029317513) --> "Variable violating min constraint: 0.0 <= mills1.gasOut.drhodxi_ph[9], has value: -0.645793" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:43: The following assertion has been violated at time 0.000000 ((mills1.gasOut.p_i[10] >= 0.0), mills1.gasOut.p_i[10]=-2.239576630897331e-12) --> "Variable violating min constraint: 0.0 <= mills1.gasOut.p_i[10], has value: -2.23958e-12" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.gasInlet.drhodxi_ph[2] >= 0.0), combustionChamber.gasInlet.drhodxi_ph[2]=-0.2034811045521269) --> "Variable violating min constraint: 0.0 <= combustionChamber.gasInlet.drhodxi_ph[2], has value: -0.203481" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.gasInlet.drhodxi_ph[5] >= 0.0), combustionChamber.gasInlet.drhodxi_ph[5]=-0.2037394633509579) --> "Variable violating min constraint: 0.0 <= combustionChamber.gasInlet.drhodxi_ph[5], has value: -0.203739" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.gasInlet.drhodxi_ph[6] >= 0.0), combustionChamber.gasInlet.drhodxi_ph[6]=-0.1014861662446173) --> "Variable violating min constraint: 0.0 <= combustionChamber.gasInlet.drhodxi_ph[6], has value: -0.101486" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.gasInlet.drhodxi_ph[8] >= 0.0), combustionChamber.gasInlet.drhodxi_ph[8]=-0.6041561000342486) --> "Variable violating min constraint: 0.0 <= combustionChamber.gasInlet.drhodxi_ph[8], has value: -0.604156" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.gasInlet.drhodxi_ph[9] >= 0.0), combustionChamber.gasInlet.drhodxi_ph[9]=-0.6457931029317513) --> "Variable violating min constraint: 0.0 <= combustionChamber.gasInlet.drhodxi_ph[9], has value: -0.645793" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:43: The following assertion has been violated at time 0.000000 ((combustionChamber.gasInlet.p_i[10] >= 0.0), combustionChamber.gasInlet.p_i[10]=-2.239576630897331e-12) --> "Variable violating min constraint: 0.0 <= combustionChamber.gasInlet.p_i[10], has value: -2.23958e-12" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.flueGasOutlet.drhodxi_ph[2] >= 0.0), combustionChamber.flueGasOutlet.drhodxi_ph[2]=-0.04693368815105289) --> "Variable violating min constraint: 0.0 <= combustionChamber.flueGasOutlet.drhodxi_ph[2], has value: -0.0469337" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.flueGasOutlet.drhodxi_ph[5] >= 0.0), combustionChamber.flueGasOutlet.drhodxi_ph[5]=-0.04841930242552496) --> "Variable violating min constraint: 0.0 <= combustionChamber.flueGasOutlet.drhodxi_ph[5], has value: -0.0484193" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.flueGasOutlet.drhodxi_ph[8] >= 0.0), combustionChamber.flueGasOutlet.drhodxi_ph[8]=-0.1694326232097476) --> "Variable violating min constraint: 0.0 <= combustionChamber.flueGasOutlet.drhodxi_ph[8], has value: -0.169433" warning: [fmi2Warning] combineMillandFurnace/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.flueGasOutlet.drhodxi_ph[9] >= 0.0), combustionChamber.flueGasOutlet.drhodxi_ph[9]=-0.1146991352553393) --> "Variable violating min constraint: 0.0 <= combustionChamber.flueGasOutlet.drhodxi_ph[9], has value: -0.114699" info: Result file: ../ClaRa_dev_ClaRa.Components.Mills.HardCoalMills.Check.combineMillandFurnace_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable combineMillandFurnace.combustionChamber.complexity will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.mills1.complexity will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.coalGas_join_burner4.flueGas.concatGasName will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.coalGas_join_burner4.flueGas.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.coalGas_join_burner4.flueGas.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.coalGas_join_burner4.flueGas.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.coalGas_join_burner4.flueGas.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.coalGas_join_burner4.flueGas.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.coalGas_join_burner4.flueGas.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.coalGas_join_burner4.flueGas.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.coalGas_join_burner4.flueGas.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.coalGas_join_burner4.flueGas.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.coalGas_join_burner4.flueGas.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.coalGas_join_burner4.flueGas_inlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.coalGas_join_burner4.fuelFlueGas_outlet.flueGas.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.combustionChamber.flueGas_outlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.combustionChamber.inlet.flueGas.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.combustionChamber.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.combustionChamber.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.combustionChamber.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.combustionChamber.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.combustionChamber.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.combustionChamber.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.combustionChamber.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.combustionChamber.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.combustionChamber.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.combustionChamber.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.combustionChamber.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.flueGasPressureSink.eyeOut.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.flueGasPressureSink.gas_a.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.flueGasPressureSink.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.flueGasPressureSink.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.flueGasPressureSink.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.flueGasPressureSink.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.flueGasPressureSink.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.flueGasPressureSink.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.flueGasPressureSink.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.flueGasPressureSink.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.flueGasPressureSink.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.flueGasPressureSink.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.flueGasPressureSink.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.fluelGasFlowSource1.eyeOut.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.fluelGasFlowSource1.gas_a.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.fluelGasFlowSource1.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.fluelGasFlowSource1.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.fluelGasFlowSource1.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.fluelGasFlowSource1.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.fluelGasFlowSource1.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.fluelGasFlowSource1.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.fluelGasFlowSource1.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.fluelGasFlowSource1.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.fluelGasFlowSource1.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.fluelGasFlowSource1.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.fluelGasFlowSource1.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.mills1.gas.concatGasName will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.mills1.gas.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.mills1.gas.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.mills1.gas.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.mills1.gas.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.mills1.gas.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.mills1.gas.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.mills1.gas.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.mills1.gas.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.mills1.gas.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Parameter combineMillandFurnace.mills1.gas.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.mills1.gasIn.gasType.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.mills1.gasOut.gasType.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.mills1.inlet.flueGas.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.mills1.outlet.flueGas.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.airModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.airModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.airModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.airModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.airModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.airModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.airModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.airModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.airModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.airModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.airModel.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.flueGasModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.flueGasModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.flueGasModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.flueGasModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.flueGasModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.flueGasModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.flueGasModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.flueGasModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.flueGasModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.flueGasModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.flueGasModel.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.fluid1.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.fluid1.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.fluid2.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.fluid2.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.fluid3.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable combineMillandFurnace.simCenter.fluid3.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0-main/Components/Furnace/SimpleCombustionChamber.mo:170:3-170:90:writable] | | | | The following assertion has been violated at time 8.000000 | | | | ((combustionChamber.summary.lambda >= 1.0), combustionChamber.summary.lambda=0.1012366679732347) --> "Not enough oxygen for complete combustion incombineMillandFurnace.combustionChamber!" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0-main/Components/Furnace/SimpleCombustionChamber.mo:170:3-170:90:writable] | | | | The following assertion has been violated at time 8.000000 | | | | ((combustionChamber.summary.lambda >= 1.0), combustionChamber.summary.lambda=0.1012366679732347) --> "Not enough oxygen for complete combustion incombineMillandFurnace.combustionChamber!" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0-main/Components/Furnace/SimpleCombustionChamber.mo:170:3-170:90:writable] | | | | The following assertion has been violated at time 8.000000 | | | | ((combustionChamber.summary.lambda >= 1.0), combustionChamber.summary.lambda=0.1012366679732347) --> "Not enough oxygen for complete combustion incombineMillandFurnace.combustionChamber!" LOG_ASSERT | error | No event found, but assert was triggered. Throwing now! error: [fmi2logger] [fmi2Error] combineMillandFurnace/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0-main/Components/Furnace/SimpleCombustionChamber.mo:170: The following assertion has been violated at time 8.000000 ((combustionChamber.summary.lambda >= 1.0), combustionChamber.summary.lambda=0.1012366679732347) --> "Not enough oxygen for complete combustion incombineMillandFurnace.combustionChamber!" error: [fmi2logger] [fmi2Error] combineMillandFurnace/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "combineMillandFurnace.root.combineMillandFurnace" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0-main/Components/Furnace/SimpleCombustionChamber.mo:170:3-170:90:writable] | | | | The following assertion has been violated at time 8.000000 | | | | ((combustionChamber.summary.lambda >= 1.0), combustionChamber.summary.lambda=0.1012366679732347) --> "Not enough oxygen for complete combustion incombineMillandFurnace.combustionChamber!" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 21 warnings info: 3 errors