(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ClaRa_dev_ClaRa.Components.Furnace.Check.Test_CombustionChamber_control_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ClaRa_dev_ClaRa_Components_Furnace_Check_Test_CombustionChamber_control_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=180 --stepSize=0.072 --mode=cs --timeout=240 --tolerance=1e-06 ../ClaRa_dev_ClaRa_Components_Furnace_Check_Test_CombustionChamber_control_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ClaRa.Components.Furnace.Check.Test_CombustionChamber_control (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 180.000000 - tolerance : 1e-06 - stepSize : 0.072 warning: [fmi2Warning] Test_CombustionChamber_control/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.gasInlet.drhodxi_ph[9] >= 0.0), combustionChamber.gasInlet.drhodxi_ph[9]=-1.12029360005545) --> "Variable violating min constraint: 0.0 <= combustionChamber.gasInlet.drhodxi_ph[9], has value: -1.12029" warning: [fmi2Warning] Test_CombustionChamber_control/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.gasInlet.drhodxi_ph[8] >= 0.0), combustionChamber.gasInlet.drhodxi_ph[8]=-1.01352239639941) --> "Variable violating min constraint: 0.0 <= combustionChamber.gasInlet.drhodxi_ph[8], has value: -1.01352" warning: [fmi2Warning] Test_CombustionChamber_control/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.gasInlet.drhodxi_ph[6] >= 0.0), combustionChamber.gasInlet.drhodxi_ph[6]=-0.2068097821550177) --> "Variable violating min constraint: 0.0 <= combustionChamber.gasInlet.drhodxi_ph[6], has value: -0.20681" warning: [fmi2Warning] Test_CombustionChamber_control/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.gasInlet.drhodxi_ph[5] >= 0.0), combustionChamber.gasInlet.drhodxi_ph[5]=-0.3546657404329494) --> "Variable violating min constraint: 0.0 <= combustionChamber.gasInlet.drhodxi_ph[5], has value: -0.354666" warning: [fmi2Warning] Test_CombustionChamber_control/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.gasInlet.drhodxi_ph[2] >= 0.0), combustionChamber.gasInlet.drhodxi_ph[2]=-0.3548089959526785) --> "Variable violating min constraint: 0.0 <= combustionChamber.gasInlet.drhodxi_ph[2], has value: -0.354809" warning: [fmi2Warning] Test_CombustionChamber_control/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.flueGasOutlet.drhodxi_ph[2] >= 0.0), combustionChamber.flueGasOutlet.drhodxi_ph[2]=-0.05045886803476166) --> "Variable violating min constraint: 0.0 <= combustionChamber.flueGasOutlet.drhodxi_ph[2], has value: -0.0504589" warning: [fmi2Warning] Test_CombustionChamber_control/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.flueGasOutlet.drhodxi_ph[5] >= 0.0), combustionChamber.flueGasOutlet.drhodxi_ph[5]=-0.05192423928510281) --> "Variable violating min constraint: 0.0 <= combustionChamber.flueGasOutlet.drhodxi_ph[5], has value: -0.0519242" warning: [fmi2Warning] Test_CombustionChamber_control/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.flueGasOutlet.drhodxi_ph[8] >= 0.0), combustionChamber.flueGasOutlet.drhodxi_ph[8]=-0.1790600416308744) --> "Variable violating min constraint: 0.0 <= combustionChamber.flueGasOutlet.drhodxi_ph[8], has value: -0.17906" warning: [fmi2Warning] Test_CombustionChamber_control/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:41: The following assertion has been violated at time 0.000000 ((combustionChamber.flueGasOutlet.drhodxi_ph[9] >= 0.0), combustionChamber.flueGasOutlet.drhodxi_ph[9]=-0.126248664424685) --> "Variable violating min constraint: 0.0 <= combustionChamber.flueGasOutlet.drhodxi_ph[9], has value: -0.126249" warning: [fmi2Warning] Test_CombustionChamber_control/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.9.0-ClaRa/BaseClasses/PartialGas_pT.mo:43: The following assertion has been violated at time 0.000000 ((combustionChamber.flueGasOutlet.p_i[10] >= 0.0), combustionChamber.flueGasOutlet.p_i[10]=-691.4902236427573) --> "Variable violating min constraint: 0.0 <= combustionChamber.flueGasOutlet.p_i[10], has value: -691.49" info: Result file: ../ClaRa_dev_ClaRa.Components.Furnace.Check.Test_CombustionChamber_control_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable Test_CombustionChamber_control.combustionChamber.complexity will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.coalGas_join.flueGas.concatGasName will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.coalGas_join.flueGas.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.coalGas_join.flueGas.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.coalGas_join.flueGas.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.coalGas_join.flueGas.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.coalGas_join.flueGas.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.coalGas_join.flueGas.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.coalGas_join.flueGas.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.coalGas_join.flueGas.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.coalGas_join.flueGas.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.coalGas_join.flueGas.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.coalGas_join.flueGas_inlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.coalGas_join.fuelFlueGas_outlet.flueGas.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.combustionChamber.flueGas_outlet.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.combustionChamber.inlet.flueGas.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.combustionChamber.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.combustionChamber.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.combustionChamber.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.combustionChamber.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.combustionChamber.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.combustionChamber.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.combustionChamber.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.combustionChamber.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.combustionChamber.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.combustionChamber.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.combustionChamber.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.flueGasFlowSource.eyeOut.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.flueGasFlowSource.gas_a.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.flueGasFlowSource.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasFlowSource.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasFlowSource.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasFlowSource.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasFlowSource.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasFlowSource.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasFlowSource.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasFlowSource.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasFlowSource.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasFlowSource.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasFlowSource.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.flueGasPressureSink.eyeOut.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.flueGasPressureSink.gas_a.Medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.flueGasPressureSink.medium.concatGasName will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasPressureSink.medium.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasPressureSink.medium.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasPressureSink.medium.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasPressureSink.medium.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasPressureSink.medium.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasPressureSink.medium.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasPressureSink.medium.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasPressureSink.medium.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasPressureSink.medium.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Parameter Test_CombustionChamber_control.flueGasPressureSink.medium.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.airModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.airModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.airModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.airModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.airModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.airModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.airModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.airModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.airModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.airModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.airModel.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.flueGasModel.concatGasName will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.flueGasModel.gasNames[1] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.flueGasModel.gasNames[2] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.flueGasModel.gasNames[3] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.flueGasModel.gasNames[4] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.flueGasModel.gasNames[5] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.flueGasModel.gasNames[6] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.flueGasModel.gasNames[7] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.flueGasModel.gasNames[8] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.flueGasModel.gasNames[9] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.flueGasModel.gasNames[10] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.fluid1.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.fluid1.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.fluid2.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.fluid2.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.fluid3.concatVLEFluidName will not be stored in the result file, because the signal type is not supported info: Variable Test_CombustionChamber_control.simCenter.fluid3.vleFluidNames[1] will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0-main/Components/Furnace/SimpleCombustionChamber.mo:170:3-170:90:writable] | | | | The following assertion has been violated at time 15.264000 | | | | ((combustionChamber.summary.lambda >= 1.0), combustionChamber.summary.lambda=0.7576621116166492) --> "Not enough oxygen for complete combustion inTest_CombustionChamber_control.combustionChamber!" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0-main/Components/Furnace/SimpleCombustionChamber.mo:170:3-170:90:writable] | | | | The following assertion has been violated at time 15.264000 | | | | ((combustionChamber.summary.lambda >= 1.0), combustionChamber.summary.lambda=0.7576621116166492) --> "Not enough oxygen for complete combustion inTest_CombustionChamber_control.combustionChamber!" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0-main/Components/Furnace/SimpleCombustionChamber.mo:170:3-170:90:writable] | | | | The following assertion has been violated at time 15.264000 | | | | ((combustionChamber.summary.lambda >= 1.0), combustionChamber.summary.lambda=0.7576621116166492) --> "Not enough oxygen for complete combustion inTest_CombustionChamber_control.combustionChamber!" LOG_ASSERT | error | No event found, but assert was triggered. Throwing now! error: [fmi2logger] [fmi2Error] Test_CombustionChamber_control/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0-main/Components/Furnace/SimpleCombustionChamber.mo:170: The following assertion has been violated at time 15.264000 ((combustionChamber.summary.lambda >= 1.0), combustionChamber.summary.lambda=0.7576621116166492) --> "Not enough oxygen for complete combustion inTest_CombustionChamber_control.combustionChamber!" error: [fmi2logger] [fmi2Error] Test_CombustionChamber_control/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "Test_CombustionChamber_control.root.Test_CombustionChamber_control" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0-main/Components/Furnace/SimpleCombustionChamber.mo:170:3-170:90:writable] | | | | The following assertion has been violated at time 15.264000 | | | | ((combustionChamber.summary.lambda >= 1.0), combustionChamber.summary.lambda=0.7576621116166492) --> "Not enough oxygen for complete combustion inTest_CombustionChamber_control.combustionChamber!" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 10 warnings info: 3 errors