(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Chemical_master_Chemical_Obsolete_Examples_HydrogenCombustion_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=0.39 --stepSize=0.000156 --mode=cs --timeout=240 --tolerance=1e-06 ../Chemical_master_Chemical_Obsolete_Examples_HydrogenCombustion_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Chemical.Obsolete.Examples.HydrogenCombustion (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 0.390000 - tolerance : 1e-06 - stepSize : 0.000156 warning: [fmi2Warning] HydrogenCombustion/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.1-master/Obsolete.mo:14347: The following assertion has been violated at time 0.000000 ((idealGas.mass >= 0.0 and idealGas.mass <= 0.0), idealGas.mass=0.01848341288) --> "Variable violating min/max constraint: 0.0 <= idealGas.mass <= 0.0, has value: 0.0184834" warning: [fmi2Warning] HydrogenCombustion/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.1-master/Obsolete.mo:14160: The following assertion has been violated at time 0.000000 ((H2O_gas.solution.n >= 0.0 and H2O_gas.solution.n <= 0.0), H2O_gas.solution.n=1.039) --> "Variable violating min/max constraint: 0.0 <= H2O_gas.solution.n <= 0.0, has value: 1.039" warning: [fmi2Warning] HydrogenCombustion/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.1-master/Obsolete.mo:14347: The following assertion has been violated at time 0.000000 ((idealGas1.mass >= 0.0 and idealGas1.mass <= 0.0), idealGas1.mass=0.01848367728) --> "Variable violating min/max constraint: 0.0 <= idealGas1.mass <= 0.0, has value: 0.0184837" warning: [fmi2Warning] HydrogenCombustion/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical 2.0.1-master/Obsolete.mo:14160: The following assertion has been violated at time 0.000000 ((H2O_gas1.solution.n >= 0.0 and H2O_gas1.solution.n <= 0.0), H2O_gas1.solution.n=1.039) --> "Variable violating min/max constraint: 0.0 <= H2O_gas1.solution.n <= 0.0, has value: 1.039" info: Result file: Chemical_master_Chemical_Obsolete_Examples_HydrogenCombustion_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter HydrogenCombustion.H2O_gas.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Parameter HydrogenCombustion.H2O_gas1.substanceData.data.name will not be stored in the result file, because the signal type is not supported info: Parameter HydrogenCombustion.H2_gas.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Parameter HydrogenCombustion.H2_gas1.substanceData.data.name will not be stored in the result file, because the signal type is not supported info: Parameter HydrogenCombustion.O2_gas.substanceData.References[1] will not be stored in the result file, because the signal type is not supported info: Parameter HydrogenCombustion.O2_gas1.substanceData.data.name will not be stored in the result file, because the signal type is not supported info: 4 warnings info: 0 errors