(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneTwoIdenticalOutputVariables_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_OneZoneTwoIdenticalOutputVariables_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=432000 --stepSize=172.8 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_OneZoneTwoIdenticalOutputVariables_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneTwoIdenticalOutputVariables (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 432000.000000 - tolerance : 1e-06 - stepSize : 172.8 LOG_STDOUT | warning | The nominal value of zon.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.11.14 00:10 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output OneZoneTwoIdenticalOutputVariables.equEle.y has in Modelica the unit 1. LOG_STDOUT | info | Output OneZoneTwoIdenticalOutputVariables.equEle2.y has in Modelica the unit 1. warning: [fmi2Warning] OneZoneTwoIdenticalOutputVariables/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20: The following assertion has been violated at time 0.000000 ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5), duc.m_flow=-6.59347278997302e-15) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" info: Result file: ../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneTwoIdenticalOutputVariables_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter OneZoneTwoIdenticalOutputVariables.building.epwName will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneTwoIdenticalOutputVariables.building.idfName will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneTwoIdenticalOutputVariables.building.weaName will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneTwoIdenticalOutputVariables.equEle.key will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneTwoIdenticalOutputVariables.equEle.name will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneTwoIdenticalOutputVariables.equEle2.key will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneTwoIdenticalOutputVariables.equEle2.name will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneTwoIdenticalOutputVariables.zon.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneTwoIdenticalOutputVariables.zon.zoneName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 600.000000 | | | | ((noEvent(zon.vol.medium.T <= 423.15)), zon.vol.medium.T=441.578934957342) --> "In OneZoneTwoIdenticalOutputVariables.zon.vol.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 600.000000 | | | | ((noEvent(zon.vol.medium.p >= 0.0)), zon.vol.medium.p=-1376650.32597857) --> "Pressure (= -1.37665e+06 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 441.579 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 600.000000 | | | | ((noEvent(zon.vol.medium.p >= 0.0)), zon.vol.medium.p=-1376650.32597857) --> "Pressure (= -1.37665e+06 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 260.911 K)" error: [fmi2logger] [fmi2Error] OneZoneTwoIdenticalOutputVariables/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/ThermalZones/EnergyPlus_24_2_0/BaseClasses/ThermalZoneAdapter.mo:312: The following assertion has been violated at time 600.000000 ((zon.vol.medium.p > 3e4), zon.vol.medium.p=-1376650.32597857) --> "In OneZoneTwoIdenticalOutputVariables.zon.fmuZon: Air pressure is below physically reasonable limit. Require 30000 < p < 110000, but p = -1.37665e+06 Pa. Model seems to have exhaust air but no supply air or infiltration." error: [fmi2logger] [fmi2Error] OneZoneTwoIdenticalOutputVariables/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "OneZoneTwoIdenticalOutputVariables.root.OneZoneTwoIdenticalOutputVariables" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 600.000000 | | | | ((noEvent(zon.vol.medium.T <= 423.15)), zon.vol.medium.T=441.578934957342) --> "In OneZoneTwoIdenticalOutputVariables.zon.vol.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 600.000000 | | | | ((noEvent(zon.vol.medium.p >= 0.0)), zon.vol.medium.p=-1376650.32597857) --> "Pressure (= -1.37665e+06 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 441.579 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 600.000000 | | | | ((noEvent(zon.vol.medium.p >= 0.0)), zon.vol.medium.p=-1376650.32597857) --> "Pressure (= -1.37665e+06 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 260.911 K)" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error terminate called without an active exception Aborted (core dumped)