(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_OneZoneOneOutputVariableSummer_OMSimulator-cs-euler_fmu --startTime=1.87488e+07 --stopTime=1.93536e+07 --stepSize=240.669 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_OneZoneOneOutputVariableSummer_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer (co-simulation) - fmiVersion: 2.0 - startTime : 18748800.000000 - stopTime : 19353600.000000 - tolerance : 1e-06 - stepSize : 240.669 LOG_STDOUT | warning | The nominal value of zon.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.11.14 00:10 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 08/06/2006 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output OneZoneOneOutputVariableSummer.equEle.y has in Modelica the unit 1. warning: [fmi2Warning] OneZoneOneOutputVariableSummer/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20: The following assertion has been violated at time 18748800.000000 ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5), duc.m_flow=-6.59347278997302e-15) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" info: Result file: ../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter OneZoneOneOutputVariableSummer.building.epwName will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneOneOutputVariableSummer.building.idfName will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneOneOutputVariableSummer.building.weaName will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneOneOutputVariableSummer.equEle.key will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneOneOutputVariableSummer.equEle.name will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneOneOutputVariableSummer.zon.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneOneOutputVariableSummer.zon.zoneName will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] OneZoneOneOutputVariableSummer/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/ThermalZones/EnergyPlus_24_2_0/BaseClasses/ThermalZoneAdapter.mo:309: The following assertion has been violated at time 18749400.000000 ((zon.vol.medium.p < 1.1e5), zon.vol.medium.p=438050.2818474669) --> "In OneZoneOneOutputVariableSummer.zon.fmuZon: Air pressure is above physically reasonable limit. Require 30000 < p < 110000, but p = 438050 Pa. Model seems to have fresh air supply but no exhaust air or exfiltration." error: [fmi2logger] [fmi2Error] OneZoneOneOutputVariableSummer/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "OneZoneOneOutputVariableSummer.root.OneZoneOneOutputVariableSummer" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error terminate called without an active exception Aborted (core dumped)