(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating_Autosizing_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_AirHeating_Autosizing_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_AirHeating_Autosizing_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating_Autosizing (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 86400.000000 - tolerance : 1e-06 - stepSize : 34.56 LOG_STDOUT | warning | The nominal value of zon.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.11.17 07:33 Initializing Response Factors Calculating CTFs for "CEILING:GARAGE" Calculating CTFs for "CEILING:LIVING" Calculating CTFs for "EXTWALL:GARAGE" Calculating CTFs for "EXTWALL:LIVING" Calculating CTFs for "FLOOR:GARAGE" Calculating CTFs for "FLOOR:LIVING" Calculating CTFs for "GABLE" Calculating CTFs for "GARAGE:STEELDOOR" Calculating CTFs for "INTERIORWALL" Calculating CTFs for "ROOF" Initializing Window Optical Properties Initializing Solar Calculations Allocate Solar Module Arrays Initializing Zone and Enclosure Report Variables Initializing Surface (Shading) Report Variables Determining Shadowing Combinations Computing Window Shade Absorption Factors Proceeding with Initializing Solar Calculations Initializing Surfaces Initializing Outdoor environment for Surfaces Setting up Surface Reporting Variables Initializing Temperature and Flux Histories Initializing Window Shading Computing Interior Absorption Factors Computing Interior Diffuse Solar Absorption Factors Initializing Solar Heat Gains Initializing Internal Heat Gains Initializing Interior Solar Distribution Initializing Interior Convection Coefficients Gathering Information for Predefined Reporting Completed Initializing Surface Heat Balance Calculate Outside Surface Heat Balance Calculate Inside Surface Heat Balance Calculate Air Heat Balance Initializing HVAC Warming up Warming up Warming up Warming up Warming up Warming up Performing Zone Sizing Simulation ...for Sizing Period: #1 CHICAGO_IL_USA ANNUAL COOLING 1% DESIGN CONDITIONS DB/MCWB Warming up Warming up Warming up Warming up Warming up Warming up Performing Zone Sizing Simulation ...for Sizing Period: #2 CHICAGO_IL_USA ANNUAL HEATING 99% DESIGN CONDITIONS DB Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD warning: [fmi2Warning] AirHeating_Autosizing/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20: The following assertion has been violated at time 0.000000 ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5), duc.m_flow=-6.594025762751698e-15) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59403e-15" info: Result file: ../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating_Autosizing_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter AirHeating_Autosizing.building.epwName will not be stored in the result file, because the signal type is not supported info: Parameter AirHeating_Autosizing.building.idfName will not be stored in the result file, because the signal type is not supported info: Parameter AirHeating_Autosizing.building.weaName will not be stored in the result file, because the signal type is not supported info: Parameter AirHeating_Autosizing.sizSysHea.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter AirHeating_Autosizing.zon.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter AirHeating_Autosizing.zon.zoneName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 22118.400000 | | | | ((noEvent(zon.vol.medium.T >= 200.0)), zon.vol.medium.T=46.15792978127075) --> "In AirHeating_Autosizing.zon.vol.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 22118.400000 | | | | ((noEvent(zon.vol.medium.T >= 200.0)), zon.vol.medium.T=46.15792978127072) --> "In AirHeating_Autosizing.zon.vol.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 22118.400000 | | | | ((noEvent(zon.vol.medium.T >= 200.0)), zon.vol.medium.T=46.15792978127072) --> "In AirHeating_Autosizing.zon.vol.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | error | No event found, but assert was triggered. Throwing now! error: [fmi2logger] [fmi2Error] AirHeating_Autosizing/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:149: The following assertion has been violated at time 22118.400000 ((noEvent(zon.vol.medium.T >= 200.0)), zon.vol.medium.T=46.15792978127075) --> "In AirHeating_Autosizing.zon.vol.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) as required from medium model "Buildings.Media.Air"." error: [fmi2logger] [fmi2Error] AirHeating_Autosizing/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "AirHeating_Autosizing.root.AirHeating_Autosizing" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 22118.400000 | | | | ((noEvent(zon.vol.medium.T >= 200.0)), zon.vol.medium.T=46.1579297812707) --> "In AirHeating_Autosizing.zon.vol.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 917, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error terminate called without an active exception Aborted (core dumped)