(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_AirHeating_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_AirHeating_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 86400.000000 - tolerance : 1e-06 - stepSize : 34.56 LOG_STDOUT | warning | The nominal value of zon.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.11.17 07:33 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD warning: [fmi2Warning] AirHeating/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20: The following assertion has been violated at time 0.000000 ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5), duc.m_flow=-6.594025762751698e-15) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59403e-15" info: Result file: ../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter AirHeating.building.epwName will not be stored in the result file, because the signal type is not supported info: Parameter AirHeating.building.idfName will not be stored in the result file, because the signal type is not supported info: Parameter AirHeating.building.weaName will not be stored in the result file, because the signal type is not supported info: Parameter AirHeating.zon.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter AirHeating.zon.zoneName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating/632.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_AirHeating_functions.c:2181: Invalid root: (-18.6392)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating/632.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_AirHeating_functions.c:2191: Invalid root: (-18.6392)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating/632.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_AirHeating_functions.c:2230: Invalid root: (-18.6392)^(-1.25) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating/632.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_AirHeating_functions.c:2240: Invalid root: (-18.6392)^(-1.25) error: [fmi2logger] [fmi2Error] AirHeating/logFmi2Call: fmi2DoStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "AirHeating.root.AirHeating" LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating/632.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_AirHeating_functions.c:2181: Invalid root: (-18.6392)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating/632.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_AirHeating_functions.c:2191: Invalid root: (-18.6392)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating/632.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_AirHeating_functions.c:2230: Invalid root: (-18.6392)^(-1.25) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.AirHeating/632.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_AirHeating_functions.c:2240: Invalid root: (-18.6392)^(-1.25) error: [fmi2logger] [fmi2Error] AirHeating/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable mSetFan2_flow.u Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 917, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error terminate called without an active exception Aborted (core dumped)