(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.Fluid.HeatExchangers.CoolingTowers.Validation.MerkelEnergyPlus_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_Fluid_HeatExchangers_CoolingTowers_Validation_MerkelEnergyPlus_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=172800 --stepSize=27.6879 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_latest_Buildings_Fluid_HeatExchangers_CoolingTowers_Validation_MerkelEnergyPlus_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.Fluid.HeatExchangers.CoolingTowers.Validation.MerkelEnergyPlus (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 172800.000000 - tolerance : 1e-06 - stepSize : 27.6879 warning: [fmi2Warning] MerkelEnergyPlus/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27: The following assertion has been violated at time 0.000000 ((dat.PFan_Q_flow_nominal >= -0.1 and dat.PFan_Q_flow_nominal <= 0.0), dat.PFan_Q_flow_nominal=0.00851552089605135) --> "Variable violating min/max constraint: -0.1 <= dat.PFan_Q_flow_nominal <= 0.0, has value: 0.00851552" warning: [fmi2Warning] MerkelEnergyPlus/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27: The following assertion has been violated at time 0.000000 ((tow.dat.PFan_Q_flow_nominal >= -0.1 and tow.dat.PFan_Q_flow_nominal <= 0.0), tow.dat.PFan_Q_flow_nominal=0.00851552089605135) --> "Variable violating min/max constraint: -0.1 <= tow.dat.PFan_Q_flow_nominal <= 0.0, has value: 0.00851552" warning: [fmi2Warning] MerkelEnergyPlus/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27: The following assertion has been violated at time 0.000000 ((tow.per.dat.PFan_Q_flow_nominal >= -0.1 and tow.per.dat.PFan_Q_flow_nominal <= 0.0), tow.per.dat.PFan_Q_flow_nominal=0.00851552089605135) --> "Variable violating min/max constraint: -0.1 <= tow.per.dat.PFan_Q_flow_nominal <= 0.0, has value: 0.00851552" info: Result file: ../Buildings_latest_Buildings.Fluid.HeatExchangers.CoolingTowers.Validation.MerkelEnergyPlus_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter MerkelEnergyPlus.datRea.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter MerkelEnergyPlus.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Parameter MerkelEnergyPlus.datRea.tableName will not be stored in the result file, because the signal type is not supported info: 3 warnings info: 0 errors