(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC_OMSimulator-cs-euler_fmu --startTime=1.5552e+07 --stopTime=1.56384e+07 --stepSize=34.56 --mode=cs --timeout=240 --tolerance=1e-07 ../Buildings_latest_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC (co-simulation) - fmiVersion: 2.0 - startTime : 15552000.000000 - stopTime : 15638400.000000 - tolerance : 1e-07 - stepSize : 34.56 info: Result file: ../Buildings_latest_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter RoomHVAC.baseCase.weaDat.filNam will not be stored in the result file, because the signal type is not supported info: Parameter RoomHVAC.hvaCon.weaDat.filNam will not be stored in the result file, because the signal type is not supported info: Parameter RoomHVAC.hvaCon2.weaDat.filNam will not be stored in the result file, because the signal type is not supported info: Parameter RoomHVAC.rooCon.weaDat.filNam will not be stored in the result file, because the signal type is not supported info: Parameter RoomHVAC.rooCon2.weaDat.filNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.p >= 0.0)), hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.p=-33143.78323868186) --> "Pressure (= -33143.8 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 630.815 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.T <= 423.15)), hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.T=630.8146409685097) --> "In RoomHVAC.hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | (((-hvaCon.fan.dp) <= hvaCon.fan.dpMax), hvaCon.fan.dp=-134468.7832386892, hvaCon.fan.dpMax=2000) --> "In RoomHVAC.hvaCon.fan: Model operates with head -dp = 134469 Pa, | | | | exceeding the pressure allowed by the parameter RoomHVAC.hvaCon.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.p >= 0.0)), baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.p=-33143.78393891803) --> "Pressure (= -33143.8 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 630.815 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.T <= 423.15)), baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.T=630.8146368243472) --> "In RoomHVAC.baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | (((-baseCase.fan.dp) <= baseCase.fan.dpMax), baseCase.fan.dp=-146535.9264382626, baseCase.fan.dpMax=2000) --> "In RoomHVAC.baseCase.fan: Model operates with head -dp = 146536 Pa, | | | | exceeding the pressure allowed by the parameter RoomHVAC.baseCase.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.p >= 0.0)), hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.p=-33143.78323855876) --> "Pressure (= -33143.8 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 630.815 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.T <= 423.15)), hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.T=630.8146409694493) --> "In RoomHVAC.hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((hvaCon2.fan.dpMachine <= hvaCon2.fan.dpMax), hvaCon2.fan.dpMachine=134468.783238566, hvaCon2.fan.dpMax=2000) --> "In RoomHVAC.hvaCon2.fan: Model operates with head -dp = 134469 Pa, | | | | exceeding the pressure allowed by the parameter RoomHVAC.hvaCon2.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((hvaCon2.fan.dpMachine <= hvaCon2.fan.dpMax), hvaCon2.fan.dpMachine=134468.783238566, hvaCon2.fan.dpMax=2000) --> "In RoomHVAC.hvaCon2.fan: Model operates with head -dp = 134469 Pa, | | | | exceeding the pressure allowed by the parameter RoomHVAC.hvaCon2.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.T <= 423.15)), hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.T=630.8146409694493) --> "In RoomHVAC.hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.p >= 0.0)), hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.p=-33143.78323855876) --> "Pressure (= -33143.8 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 630.815 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | (((-baseCase.fan.dp) <= baseCase.fan.dpMax), baseCase.fan.dp=-146535.9264382626, baseCase.fan.dpMax=2000) --> "In RoomHVAC.baseCase.fan: Model operates with head -dp = 146536 Pa, | | | | exceeding the pressure allowed by the parameter RoomHVAC.baseCase.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.T <= 423.15)), baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.T=630.8146368243472) --> "In RoomHVAC.baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.p >= 0.0)), baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.p=-33143.78393891803) --> "Pressure (= -33143.8 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 630.815 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | (((-hvaCon.fan.dp) <= hvaCon.fan.dpMax), hvaCon.fan.dp=-134468.7832386892, hvaCon.fan.dpMax=2000) --> "In RoomHVAC.hvaCon.fan: Model operates with head -dp = 134469 Pa, | | | | exceeding the pressure allowed by the parameter RoomHVAC.hvaCon.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.T <= 423.15)), hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.T=630.8146409685097) --> "In RoomHVAC.hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.p >= 0.0)), hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.p=-33143.78323868186) --> "Pressure (= -33143.8 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 630.815 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((hvaCon2.fan.dpMachine <= hvaCon2.fan.dpMax), hvaCon2.fan.dpMachine=134468.783238566, hvaCon2.fan.dpMax=2000) --> "In RoomHVAC.hvaCon2.fan: Model operates with head -dp = 134469 Pa, | | | | exceeding the pressure allowed by the parameter RoomHVAC.hvaCon2.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.T <= 423.15)), hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.T=630.8146409694493) --> "In RoomHVAC.hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.p >= 0.0)), hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.p=-33143.78323855876) --> "Pressure (= -33143.8 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 630.815 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | (((-baseCase.fan.dp) <= baseCase.fan.dpMax), baseCase.fan.dp=-146535.9264382626, baseCase.fan.dpMax=2000) --> "In RoomHVAC.baseCase.fan: Model operates with head -dp = 146536 Pa, | | | | exceeding the pressure allowed by the parameter RoomHVAC.baseCase.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.T <= 423.15)), baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.T=630.8146368243472) --> "In RoomHVAC.baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.p >= 0.0)), baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.p=-33143.78393891803) --> "Pressure (= -33143.8 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 630.815 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | (((-hvaCon.fan.dp) <= hvaCon.fan.dpMax), hvaCon.fan.dp=-134468.7832386892, hvaCon.fan.dpMax=2000) --> "In RoomHVAC.hvaCon.fan: Model operates with head -dp = 134469 Pa, | | | | exceeding the pressure allowed by the parameter RoomHVAC.hvaCon.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.T <= 423.15)), hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.T=630.8146409685097) --> "In RoomHVAC.hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.p >= 0.0)), hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.p=-33143.78323868186) --> "Pressure (= -33143.8 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 630.815 K)" LOG_ASSERT | error | No event found, but assert was triggered. Throwing now! error: [fmi2logger] [fmi2Error] RoomHVAC/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154: The following assertion has been violated at time 15552069.120000 ((noEvent(hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.p >= 0.0)), hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.p=-33143.78323868186) --> "Pressure (= -33143.8 Pa) of medium "Buildings.Media.Air" is negative (Temperature = 630.815 K)" error: [fmi2logger] [fmi2Error] RoomHVAC/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "RoomHVAC.root.RoomHVAC" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.p >= 0.0)), hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.p=-33143.78323868186) --> "Pressure (= -33143.8 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 630.815 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.T <= 423.15)), hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium.T=630.8146409685097) --> "In RoomHVAC.hvaCon.cooCoi.heaCooHum_u.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | (((-hvaCon.fan.dp) <= hvaCon.fan.dpMax), hvaCon.fan.dp=-134468.7832386892, hvaCon.fan.dpMax=2000) --> "In RoomHVAC.hvaCon.fan: Model operates with head -dp = 134469 Pa, | | | | exceeding the pressure allowed by the parameter RoomHVAC.hvaCon.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.p >= 0.0)), baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.p=-33143.78393891803) --> "Pressure (= -33143.8 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 630.815 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.T <= 423.15)), baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium.T=630.8146368243472) --> "In RoomHVAC.baseCase.cooCoi.heaCooHum_u.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | (((-baseCase.fan.dp) <= baseCase.fan.dpMax), baseCase.fan.dp=-146535.9264382626, baseCase.fan.dpMax=2000) --> "In RoomHVAC.baseCase.fan: Model operates with head -dp = 146536 Pa, | | | | exceeding the pressure allowed by the parameter RoomHVAC.baseCase.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.p >= 0.0)), hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.p=-33143.78323855876) --> "Pressure (= -33143.8 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = 630.815 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((noEvent(hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.T <= 423.15)), hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium.T=630.8146409694493) --> "In RoomHVAC.hvaCon2.cooCoi.heaCooHum_u.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((hvaCon2.fan.dpMachine <= hvaCon2.fan.dpMax), hvaCon2.fan.dpMachine=134468.783238566, hvaCon2.fan.dpMax=2000) --> "In RoomHVAC.hvaCon2.fan: Model operates with head -dp = 134469 Pa, | | | | exceeding the pressure allowed by the parameter RoomHVAC.hvaCon2.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 3 errors