(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.DHC.Examples.Combined.ETSHeatRecoveryHeatPump_BuildingTimeSeries.WithDHW_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_DHC_Examples_Combined_ETSHeatRecoveryHeatPump_BuildingTimeSeries_WithDHW_OMSimulator-cs-euler_fmu --startTime=7.776e+06 --stopTime=8.64e+06 --stepSize=345.6 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_latest_Buildings_DHC_Examples_Combined_ETSHeatRecoveryHeatPump_BuildingTimeSeries_WithDHW_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.DHC.Examples.Combined.ETSHeatRecoveryHeatPump_BuildingTimeSeries.WithDHW (co-simulation) - fmiVersion: 2.0 - startTime : 7776000.000000 - stopTime : 8640000.000000 - tolerance : 1e-06 - stepSize : 345.6 LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmp5npfw38f/WithDHW-7sudds6c/temp/0001_WithDHW/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Resources/Data/DHC/Loads/Examples/JBA_All_futu_tendays.mos" LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmp5npfw38f/WithDHW-7sudds6c/temp/0001_WithDHW/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Resources/Data/DHC/Loads/Examples/JBA_All_futu_tendays.mos" warning: [fmi2Warning] WithDHW/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:78: The following assertion has been violated at time 7776000.000000 ((bui.bui.terUniCoo.hexWetNtu.SHR >= 0.0 and bui.bui.terUniCoo.hexWetNtu.SHR <= 1.0), bui.bui.terUniCoo.hexWetNtu.SHR=-1.948754906176889e-07) --> "Variable violating min/max constraint: 0.0 <= bui.bui.terUniCoo.hexWetNtu.SHR <= 1.0, has value: -1.94875e-07" warning: [fmi2Warning] WithDHW/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311: The following assertion has been violated at time 7776000.000000 ((bui.ets.heaPum.pumCon.eff.yMot >= 0.0), bui.ets.heaPum.pumCon.eff.yMot=-0.004818407369347748) --> "Variable violating min constraint: 0.0 <= bui.ets.heaPum.pumCon.eff.yMot, has value: -0.00481841" warning: [fmi2Warning] WithDHW/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311: The following assertion has been violated at time 7776000.000000 ((bui.ets.heaPum.pumEva.eff.yMot >= 0.0), bui.ets.heaPum.pumEva.eff.yMot=-7.193257446381015e-15) --> "Variable violating min constraint: 0.0 <= bui.ets.heaPum.pumEva.eff.yMot, has value: -7.19326e-15" info: Result file: ../Buildings_latest_Buildings.DHC.Examples.Combined.ETSHeatRecoveryHeatPump_BuildingTimeSeries.WithDHW_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable WithDHW.bui.bui.filNam will not be stored in the result file, because the signal type is not supported info: Parameter WithDHW.bui.bui.loa.delimiter will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.bui.loa.tableName will not be stored in the result file, because the signal type is not supported info: Parameter WithDHW.bui.datHeaPum.datHea.devIde will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.datHeaPum.datHeaSca.devIde will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.datHeaPum.datHeaSca.devIde will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.dat.datHeaSca.devIde will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumCoo.devIde will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.datTab.devIde will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.devIde will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabPEle.delimiter will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabPEle.fileName will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabPEle.tableName will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabQUse_flow.delimiter will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabQUse_flow.fileName will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabQUse_flow.tableName will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.bui.filNam will not be stored in the result file, because the signal type is not supported info: Parameter WithDHW.bui.loaEleNonHva.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter WithDHW.bui.loaEleNonHva.tableName will not be stored in the result file, because the signal type is not supported info: Variable WithDHW.filNam will not be stored in the result file, because the signal type is not supported info: Parameter WithDHW.wea.filNam will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] WithDHW/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Water.mo:66: The following assertion has been violated at time 7776025.359009 ((noEvent(bui.ets.junHeaWat.vol.dynBal.medium.T <= 403.15)), bui.ets.junHeaWat.vol.dynBal.medium.T=556.8189433018069) --> "In WithDHW.bui.ets.junHeaWat.vol.dynBal.medium: Temperature T = 556.819 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] WithDHW/logFmi2Call: fmi2DoStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "WithDHW.root.WithDHW" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 7776025.359009 | | | | ((noEvent(bui.ets.junHeaWat.vol.dynBal.medium.T <= 403.15)), bui.ets.junHeaWat.vol.dynBal.medium.T=556.8189433050751) --> "In WithDHW.bui.ets.junHeaWat.vol.dynBal.medium: Temperature T = 556.819 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 7776025.359009 | | | | ((noEvent(bui.ets.junChiWat.vol.dynBal.medium.T >= 272.15)), bui.ets.junChiWat.vol.dynBal.medium.T=-48.7201812505819) --> "In WithDHW.bui.ets.junChiWat.vol.dynBal.medium: Temperature T = -48.7202 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 7776025.359009 | | | | ((noEvent(bui.ets.tanDhw.theMixVal.jun.vol.dynBal.medium.T >= 272.15)), bui.ets.tanDhw.theMixVal.jun.vol.dynBal.medium.T=233.6197913583938) --> "In WithDHW.bui.ets.tanDhw.theMixVal.jun.vol.dynBal.medium: Temperature T = 233.62 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 3 warnings info: 3 errors