(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctMixConDischargeSensor.Validation.Controller_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctMixConDischargeSensor_Validation_Controller_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctMixConDischargeSensor_Validation_Controller_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctMixConDischargeSensor.Validation.Controller (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 86400.000000 - tolerance : 1e-06 - stepSize : 34.56 warning: [fmi2Warning] Controller/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated during initialization at time 0.000000 ((not duaDucCon.ala.truDel7.y), duaDucCon.ala.truDel7.y=true) --> "Warning: the cold-duct or hot-dcut damper is leaking." info: Result file: ../Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctMixConDischargeSensor.Validation.Controller_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable Controller.duaDucCon.ala.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable Controller.duaDucCon.ala.assMes1.message will not be stored in the result file, because the signal type is not supported info: Variable Controller.duaDucCon.ala.assMes6.message will not be stored in the result file, because the signal type is not supported info: Variable Controller.duaDucCon.ala.assMes7.message will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 12080.000000 | | | | ((not duaDucCon.ala.truDel6.y), duaDucCon.ala.truDel6.y=true) --> "Warning: airflow sensor should be calibrated." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 20900.000000 | | | | ((duaDucCon.ala.not2.y), duaDucCon.ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 20900.000000 | | | | ((duaDucCon.ala.not1.y), duaDucCon.ala.not1.y=false) --> "Warning: airflow is less than 50% of the setpoint." info: 1 warnings info: 0 errors