(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.Plants.Chillers.Pumps.ChilledWater.Validation.Controller_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_Plants_Chillers_Pumps_ChilledWater_Validation_Controller_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_Plants_Chillers_Pumps_ChilledWater_Validation_Controller_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.Controls.OBC.ASHRAE.G36.Plants.Chillers.Pumps.ChilledWater.Validation.Controller (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 3600.000000 - tolerance : 1e-06 - stepSize : 1.44 warning: [fmi2Warning] Controller/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/ASHRAE/G36/Plants/Chillers/Pumps/ChilledWater/Controller.mo:120: The following assertion has been violated at time 0.000000 ((heaNoLoc.yPumSpe >= max(heaNoLoc.pumSpeRemDp.minPumSpe, 0.0) and heaNoLoc.yPumSpe <= min(heaNoLoc.pumSpeRemDp.maxPumSpe, 1.0)), heaNoLoc.yPumSpe=0, heaNoLoc.pumSpeRemDp.minPumSpe=0.1, heaNoLoc.pumSpeRemDp.maxPumSpe=1) --> "Variable violating min/max constraint: max(heaNoLoc.pumSpeRemDp.minPumSpe, 0.0) <= heaNoLoc.yPumSpe <= min(heaNoLoc.pumSpeRemDp.maxPumSpe, 1.0), has value: 0" warning: [fmi2Warning] Controller/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/ASHRAE/G36/Plants/Chillers/Pumps/ChilledWater/Controller.mo:120: The following assertion has been violated at time 0.000000 ((dedNoLoc.yPumSpe >= max(dedNoLoc.pumSpeRemDp.minPumSpe, 0.0) and dedNoLoc.yPumSpe <= min(dedNoLoc.pumSpeRemDp.maxPumSpe, 1.0)), dedNoLoc.yPumSpe=0, dedNoLoc.pumSpeRemDp.minPumSpe=0.1, dedNoLoc.pumSpeRemDp.maxPumSpe=1) --> "Variable violating min/max constraint: max(dedNoLoc.pumSpeRemDp.minPumSpe, 0.0) <= dedNoLoc.yPumSpe <= min(dedNoLoc.pumSpeRemDp.maxPumSpe, 1.0), has value: 0" warning: [fmi2Warning] Controller/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/ASHRAE/G36/Plants/Chillers/Pumps/ChilledWater/Controller.mo:120: The following assertion has been violated at time 0.000000 ((dedLoc.yPumSpe >= max(dedLoc.pumSpeLocDp.minPumSpe, 0.0) and dedLoc.yPumSpe <= min(dedLoc.pumSpeLocDp.maxPumSpe, 1.0)), dedLoc.yPumSpe=0, dedLoc.pumSpeLocDp.minPumSpe=0.1, dedLoc.pumSpeLocDp.maxPumSpe=1) --> "Variable violating min/max constraint: max(dedLoc.pumSpeLocDp.minPumSpe, 0.0) <= dedLoc.yPumSpe <= min(dedLoc.pumSpeLocDp.maxPumSpe, 1.0), has value: 0" info: Result file: ../Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.Plants.Chillers.Pumps.ChilledWater.Validation.Controller_OMSimulator-cs-euler_res.mat (bufferSize=10) info: 3 warnings info: 0 errors