(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_NoOutputVariable_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_NoOutputVariable_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.NoOutputVariable (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 86400.000000 - tolerance : 1e-06 - stepSize : 34.56 EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.14 00:56 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD warning: [fmi2Warning] NoOutputVariable/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20: The following assertion has been violated at time 0.000000 ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5), duc.m_flow=-6.593472789973019e-15) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" info: Result file: Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_NoOutputVariable_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter NoOutputVariable.building.epwName will not be stored in the result file, because the signal type is not supported info: Parameter NoOutputVariable.building.idfName will not be stored in the result file, because the signal type is not supported info: Parameter NoOutputVariable.building.weaName will not be stored in the result file, because the signal type is not supported info: Parameter NoOutputVariable.zon.zoneName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 345.600000 | | | | ((noEvent(zon.vol.medium.T >= 200.0)), zon.vol.medium.T=67.33374667479563) --> "In NoOutputVariable.zon.vol.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 345.600000 | | | | ((noEvent(zon.vol.medium.T >= 200.0)), zon.vol.medium.T=67.33374667479561) --> "In NoOutputVariable.zon.vol.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 345.600000 | | | | ((noEvent(zon.vol.medium.T >= 200.0)), zon.vol.medium.T=67.33374667479561) --> "In NoOutputVariable.zon.vol.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | error | No event found, but assert was triggered. Throwing now! error: [fmi2logger] [fmi2Error] NoOutputVariable/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:149: The following assertion has been violated at time 345.600000 ((noEvent(zon.vol.medium.T >= 200.0)), zon.vol.medium.T=67.33374667479563) --> "In NoOutputVariable.zon.vol.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) as required from medium model "Buildings.Media.Air"." error: [fmi2logger] [fmi2Error] NoOutputVariable/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "NoOutputVariable.root.NoOutputVariable" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 345.600000 | | | | ((noEvent(zon.vol.medium.T >= 200.0)), zon.vol.medium.T=67.33374667479558) --> "In NoOutputVariable.zon.vol.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error terminate called without an active exception Aborted (core dumped)