(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_ASHRAE2006Spring_OMSimulator-cs-euler_fmu --startTime=7.344e+06 --stopTime=7.776e+06 --stepSize=172.8 --mode=cs --timeout=240 --tolerance=1e-07 ../Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_ASHRAE2006Spring_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Spring (co-simulation) - fmiVersion: 2.0 - startTime : 7344000.000000 - stopTime : 7776000.000000 - tolerance : 1e-07 - stepSize : 172.8 EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.14 00:55 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 03/27/2006 for SPAWN-RUNPERIOD info: Result file: Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_ASHRAE2006Spring_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter ASHRAE2006Spring.flo.att.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Spring.flo.cor.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Spring.flo.eas.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Spring.flo.epwName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Spring.flo.idfName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Spring.flo.nor.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Spring.flo.sou.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Spring.flo.weaName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Spring.flo.wes.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Spring.hvac.conVAV[1].assMes.message will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Spring.hvac.conVAV[2].assMes.message will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Spring.hvac.conVAV[3].assMes.message will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Spring.hvac.conVAV[4].assMes.message will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Spring.hvac.conVAV[5].assMes.message will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Spring.weaDat.filNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:364:5-373:38:writable] | | | | The following assertion has been violated at time 7344060.000000 | | | | ((noEvent(hvac.pumCooCoi.m_flow > (-0.1) * hvac.cooCoi.m1_flow_nominal) and noEvent(hvac.heaCoi.m2_flow > (-0.1) * hvac.cooCoi.m2_flow_nominal)), hvac.pumCooCoi.m_flow=0, hvac.cooCoi.m1_flow_nominal=1.544111458164436, hvac.heaCoi.m2_flow=-2.214200934575967, hvac.cooCoi.m2_flow_nominal=1.6466744) --> "*** Warning in ASHRAE2006Spring.hvac.cooCoi: The flow direction reversed. | | | | However, because the constant use_dynamicFlowRegime is set to false, | | | | the model does not change equations based on the actual flow regime. | | | | To switch equations based on the actual flow regime during the simulation, | | | | set the constant use_dynamicFlowRegime=true. | | | | Note that this can lead to slow simulation because of events." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/BaseClasses/PartialEffectivenessNTU.mo:178:5-187:38:writable] | | | | The following assertion has been violated at time 7344060.000000 | | | | ((noEvent(hvac.pumHeaCoi.m_flow > (-0.1) * hvac.heaCoi.m1_flow_nominal) and noEvent(hvac.heaCoi.m2_flow > (-0.1) * hvac.heaCoi.m2_flow_nominal)), hvac.pumHeaCoi.m_flow=0, hvac.heaCoi.m1_flow_nominal=0.09502224357934989, hvac.heaCoi.m2_flow=-2.214200934575967, hvac.heaCoi.m2_flow_nominal=0.4940023199999999) --> "*** Warning in ASHRAE2006Spring.hvac.heaCoi: The flow direction reversed. | | | | However, because the constant use_dynamicFlowRegime is set to false, | | | | the model does not change equations based on the actual flow regime. | | | | To switch equations based on the actual flow regime during the simulation, | | | | set the constant use_dynamicFlowRegime=true. | | | | Note that this can lead to slow simulation because of events." LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 7.34417e+06. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 7.34417e+06. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_ASSERT | debug | Solving non-linear system 8620 failed at time=7344172.8. | | | | For more information please use -lv LOG_NLS. error: [stepUntil] fmi2_doStep failed for FMU "ASHRAE2006Spring.root.ASHRAE2006Spring" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error terminate called without an active exception Aborted (core dumped)