(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_RadiantHeatingCooling_TRoom_OMSimulator-cs-euler_fmu --startTime=7.776e+06 --stopTime=9.504e+06 --stepSize=691.2 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_RadiantHeatingCooling_TRoom_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.RadiantHeatingCooling_TRoom (co-simulation) - fmiVersion: 2.0 - startTime : 7776000.000000 - stopTime : 9504000.000000 - tolerance : 1e-06 - stepSize : 691.2 EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.17 06:12 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 04/01/2006 for SPAWN-RUNPERIOD warning: [fmi2Warning] RadiantHeatingCooling_TRoom/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20: The following assertion has been violated at time 7776000.000000 ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5), duc.m_flow=-6.593472789973019e-15) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" info: Result file: Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_RadiantHeatingCooling_TRoom_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter RadiantHeatingCooling_TRoom.attFlo.surfaceName will not be stored in the result file, because the signal type is not supported info: Parameter RadiantHeatingCooling_TRoom.building.epwName will not be stored in the result file, because the signal type is not supported info: Parameter RadiantHeatingCooling_TRoom.building.idfName will not be stored in the result file, because the signal type is not supported info: Parameter RadiantHeatingCooling_TRoom.building.weaName will not be stored in the result file, because the signal type is not supported info: Parameter RadiantHeatingCooling_TRoom.livFlo.surfaceName will not be stored in the result file, because the signal type is not supported info: Parameter RadiantHeatingCooling_TRoom.zon.zoneName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:146:5-154:68:writable] | | | | The following assertion has been violated at time 7777200.000000 | | | | ((noEvent(abs(pum.prePow.Q_flow) < 836800.0 * max(0.001 * pum.vol.steBal.m_flow_small, abs(slaFlo.m_flow)))), pum.prePow.Q_flow=16574928.21758884, pum.vol.steBal.m_flow_small=3.792708571428572e-05, slaFlo.m_flow=15.01546019472102) --> "In RadiantHeatingCooling_TRoom.pum.vol.steBal: | | | | The heat flow rate equals 1.65749e+07 W and the mass flow rate equals 15.0155 kg/s, | | | | which results in a temperature difference 263.828 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:146:5-154:68:writable] | | | | The following assertion has been violated at time 7777200.000000 | | | | ((noEvent(abs(pum.prePow.Q_flow) < 836800.0 * max(0.001 * pum.vol.steBal.m_flow_small, abs(slaFlo.m_flow)))), pum.prePow.Q_flow=16574928.21758884, pum.vol.steBal.m_flow_small=3.792708571428572e-05, slaFlo.m_flow=15.01546019472102) --> "In RadiantHeatingCooling_TRoom.pum.vol.steBal: | | | | The heat flow rate equals 1.65749e+07 W and the mass flow rate equals 15.0155 kg/s, | | | | which results in a temperature difference 263.828 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." error: [fmi2logger] [fmi2Error] RadiantHeatingCooling_TRoom/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/ThermalZones/EnergyPlus_24_2_0/BaseClasses/ThermalZoneAdapter.mo:276: The following assertion has been violated at time 7777200.000000 ((zon.vol.medium.p < 1.1e5), zon.vol.medium.p=686529.2009328463) --> "In RadiantHeatingCooling_TRoom.zon.fmuZon: Air pressure is above physically reasonable limit. Require 30000 < p < 110000, but p = 686529 Pa. Model seems to have fresh air supply but no exhaust air or exfiltration." error: [fmi2logger] [fmi2Error] RadiantHeatingCooling_TRoom/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "RadiantHeatingCooling_TRoom.root.RadiantHeatingCooling_TRoom" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:146:5-154:68:writable] | | | | The following assertion has been violated at time 7777200.000000 | | | | ((noEvent(abs(pum.prePow.Q_flow) < 836800.0 * max(0.001 * pum.vol.steBal.m_flow_small, abs(slaFlo.m_flow)))), pum.prePow.Q_flow=16574928.21758884, pum.vol.steBal.m_flow_small=3.792708571428572e-05, slaFlo.m_flow=15.01546019472102) --> "In RadiantHeatingCooling_TRoom.pum.vol.steBal: | | | | The heat flow rate equals 1.65749e+07 W and the mass flow rate equals 15.0155 kg/s, | | | | which results in a temperature difference 263.828 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 917, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error terminate called without an active exception Aborted (core dumped)