(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC_OMSimulator-cs-euler_fmu --startTime=1.5552e+07 --stopTime=1.56384e+07 --stepSize=34.56 --mode=cs --timeout=240 --tolerance=1e-07 ../Buildings_13_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC (co-simulation) - fmiVersion: 2.0 - startTime : 15552000.000000 - stopTime : 15638400.000000 - tolerance : 1e-07 - stepSize : 34.56 info: Result file: Buildings_13_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter RoomHVAC.baseCase.weaDat.filNam will not be stored in the result file, because the signal type is not supported info: Parameter RoomHVAC.hvaCon.weaDat.filNam will not be stored in the result file, because the signal type is not supported info: Parameter RoomHVAC.hvaCon2.weaDat.filNam will not be stored in the result file, because the signal type is not supported info: Parameter RoomHVAC.rooCon.weaDat.filNam will not be stored in the result file, because the signal type is not supported info: Parameter RoomHVAC.rooCon2.weaDat.filNam will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] RoomHVAC/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Utilities.mo:26: Wrong boundary mass fractions in medium "Air" in model "Boundary_pT": The boundary value X_boundary(1) = -0.00327104 is negative. It must be positive. error: [fmi2logger] [fmi2Error] RoomHVAC/logFmi2Call: fmi2DoStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "RoomHVAC.root.RoomHVAC" error: [fmi2logger] [fmi2Error] RoomHVAC/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Utilities.mo:26: Wrong boundary mass fractions in medium "Air" in model "Boundary_pT": The boundary value X_boundary(1) = -0.00327104 is negative. It must be positive. error: [fmi2logger] [fmi2Error] RoomHVAC/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable hvaCon2.mWat_flow.u Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 6 errors