(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Examples_ChillerPlant_DataCenterRenewables_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=604800 --stepSize=241.92 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_Examples_ChillerPlant_DataCenterRenewables_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.Examples.ChillerPlant.DataCenterRenewables (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 604800.000000 - tolerance : 1e-06 - stepSize : 241.92 warning: [fmi2Warning] DataCenterRenewables/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/YorkCalc.mo:55: The following assertion has been violated at time 0.000000 ((dataCenterContinuousTimeControl.cooTow.TAppCor >= 0.0), dataCenterContinuousTimeControl.cooTow.TAppCor=-0.6151242852027358) --> "Variable violating min constraint: 0.0 <= dataCenterContinuousTimeControl.cooTow.TAppCor, has value: -0.615124" info: Result file: Buildings_13_Buildings_Examples_ChillerPlant_DataCenterRenewables_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter DataCenterRenewables.dataCenterContinuousTimeControl.weaData.filNam will not be stored in the result file, because the signal type is not supported info: Parameter DataCenterRenewables.winTur.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DataCenterRenewables.winTur.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((dataCenterContinuousTimeControl.cooCoi.dp2 <= dataCenterContinuousTimeControl.fan.dpMax), dataCenterContinuousTimeControl.cooCoi.dp2=13287.97620692143, dataCenterContinuousTimeControl.fan.dpMax=3000) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.fan: Model operates with head -dp = 13288 Pa, | | | | exceeding the pressure allowed by the parameter DataCenterRenewables.dataCenterContinuousTimeControl.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((dataCenterContinuousTimeControl.cooCoi.dp2 <= dataCenterContinuousTimeControl.fan.dpMax), dataCenterContinuousTimeControl.cooCoi.dp2=13287.97620692143, dataCenterContinuousTimeControl.fan.dpMax=3000) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.fan: Model operates with head -dp = 13288 Pa, | | | | exceeding the pressure allowed by the parameter DataCenterRenewables.dataCenterContinuousTimeControl.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((dataCenterContinuousTimeControl.cooCoi.dp2 <= dataCenterContinuousTimeControl.fan.dpMax), dataCenterContinuousTimeControl.cooCoi.dp2=13287.97620692143, dataCenterContinuousTimeControl.fan.dpMax=3000) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.fan: Model operates with head -dp = 13288 Pa, | | | | exceeding the pressure allowed by the parameter DataCenterRenewables.dataCenterContinuousTimeControl.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((dataCenterContinuousTimeControl.cooCoi.dp2 <= dataCenterContinuousTimeControl.fan.dpMax), dataCenterContinuousTimeControl.cooCoi.dp2=13287.97620692143, dataCenterContinuousTimeControl.fan.dpMax=3000) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.fan: Model operates with head -dp = 13288 Pa, | | | | exceeding the pressure allowed by the parameter DataCenterRenewables.dataCenterContinuousTimeControl.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((dataCenterContinuousTimeControl.cooCoi.dp2 <= dataCenterContinuousTimeControl.fan.dpMax), dataCenterContinuousTimeControl.cooCoi.dp2=13287.97620692143, dataCenterContinuousTimeControl.fan.dpMax=3000) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.fan: Model operates with head -dp = 13288 Pa, | | | | exceeding the pressure allowed by the parameter DataCenterRenewables.dataCenterContinuousTimeControl.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | Found event, previous asserts are ignored. error: [fmi2logger] [fmi2Error] DataCenterRenewables/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:63: The following assertion has been violated at time 226.101042 ((noEvent(dataCenterContinuousTimeControl.chi.vol1.dynBal.medium.T >= 272.15)), dataCenterContinuousTimeControl.chi.vol1.dynBal.medium.T=265.0400376823545) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.chi.vol1.dynBal.medium: Temperature T = 265.04 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] DataCenterRenewables/logFmi2Call: fmi2DoStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "DataCenterRenewables.root.DataCenterRenewables" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.chi.vol1.dynBal.medium.T >= 272.15)), dataCenterContinuousTimeControl.chi.vol1.dynBal.medium.T=265.0400376823384) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.chi.vol1.dynBal.medium: Temperature T = 265.04 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooTow.vol.dynBal.medium.T >= 272.15)), dataCenterContinuousTimeControl.cooTow.vol.dynBal.medium.T=237.3175839927408) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.cooTow.vol.dynBal.medium: Temperature T = 237.318 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.roo.rooVol.dynBal.medium.T >= 200.0)), dataCenterContinuousTimeControl.roo.rooVol.dynBal.medium.T=121.2302631574176) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.roo.rooVol.dynBal.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[1].vol2.dynBal.medium.p >= 0.0)), dataCenterContinuousTimeControl.cooCoi.ele[1].vol2.dynBal.medium.p=-17675148.30038648) --> "Pressure (= -1.76751e+07 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = -4875.33 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[4].vol2.dynBal.medium.T >= 200.0)), dataCenterContinuousTimeControl.cooCoi.ele[4].vol2.dynBal.medium.T=-4875.327093884893) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.cooCoi.ele[4].vol2.dynBal.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:146:5-147:72:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[4].vol2.dynBal.medium.Xi[1] >= -1e-5) and noEvent(dataCenterContinuousTimeControl.cooCoi.ele[4].vol2.dynBal.medium.Xi[1] <= 1.00001)), dataCenterContinuousTimeControl.cooCoi.ele[4].vol2.dynBal.medium.Xi[1]=-2.983460254098307) --> "Mass fraction X[1] = -2.98346 of substance water | | | | of medium "Buildings.Media.Air" is not in the range 0..1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[4].vol1.dynBal.medium.T >= 272.15)), dataCenterContinuousTimeControl.cooCoi.ele[4].vol1.dynBal.medium.T=-1850.538690381666) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.cooCoi.ele[4].vol1.dynBal.medium: Temperature T = -1850.54 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[1].vol2.dynBal.medium.p >= 0.0)), dataCenterContinuousTimeControl.cooCoi.ele[1].vol2.dynBal.medium.p=-17675148.30038648) --> "Pressure (= -1.76751e+07 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = -9491.3 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[3].vol2.dynBal.medium.T >= 200.0)), dataCenterContinuousTimeControl.cooCoi.ele[3].vol2.dynBal.medium.T=-9491.295950916003) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.cooCoi.ele[3].vol2.dynBal.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:146:5-147:72:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[3].vol2.dynBal.medium.Xi[1] >= -1e-5) and noEvent(dataCenterContinuousTimeControl.cooCoi.ele[3].vol2.dynBal.medium.Xi[1] <= 1.00001)), dataCenterContinuousTimeControl.cooCoi.ele[3].vol2.dynBal.medium.Xi[1]=-1.744401510030742) --> "Mass fraction X[1] = -1.7444 of substance water | | | | of medium "Buildings.Media.Air" is not in the range 0..1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[3].vol1.dynBal.medium.T >= 272.15)), dataCenterContinuousTimeControl.cooCoi.ele[3].vol1.dynBal.medium.T=-1850.538702602615) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.cooCoi.ele[3].vol1.dynBal.medium: Temperature T = -1850.54 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[1].vol2.dynBal.medium.p >= 0.0)), dataCenterContinuousTimeControl.cooCoi.ele[1].vol2.dynBal.medium.p=-17675148.30038648) --> "Pressure (= -1.76751e+07 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = -9491.54 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[2].vol2.dynBal.medium.T >= 200.0)), dataCenterContinuousTimeControl.cooCoi.ele[2].vol2.dynBal.medium.T=-9491.542561663595) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.cooCoi.ele[2].vol2.dynBal.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:146:5-147:72:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[2].vol2.dynBal.medium.Xi[1] >= -1e-5) and noEvent(dataCenterContinuousTimeControl.cooCoi.ele[2].vol2.dynBal.medium.Xi[1] <= 1.00001)), dataCenterContinuousTimeControl.cooCoi.ele[2].vol2.dynBal.medium.Xi[1]=-1.744401510030741) --> "Mass fraction X[1] = -1.7444 of substance water | | | | of medium "Buildings.Media.Air" is not in the range 0..1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[2].vol1.dynBal.medium.T >= 272.15)), dataCenterContinuousTimeControl.cooCoi.ele[2].vol1.dynBal.medium.T=-1850.490818061431) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.cooCoi.ele[2].vol1.dynBal.medium: Temperature T = -1850.49 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:154:3-154:148:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[1].vol2.dynBal.medium.p >= 0.0)), dataCenterContinuousTimeControl.cooCoi.ele[1].vol2.dynBal.medium.p=-17675148.30038648) --> "Pressure (= -1.76751e+07 Pa) of medium "Buildings.Media.Air" is negative | | | | (Temperature = -9491.54 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[1].vol2.dynBal.medium.T >= 200.0)), dataCenterContinuousTimeControl.cooCoi.ele[1].vol2.dynBal.medium.T=-9491.542566955348) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.cooCoi.ele[1].vol2.dynBal.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Air.mo:146:5-147:72:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[1].vol2.dynBal.medium.Xi[1] >= -1e-5) and noEvent(dataCenterContinuousTimeControl.cooCoi.ele[1].vol2.dynBal.medium.Xi[1] <= 1.00001)), dataCenterContinuousTimeControl.cooCoi.ele[1].vol2.dynBal.medium.Xi[1]=-1.744401510030743) --> "Mass fraction X[1] = -1.7444 of substance water | | | | of medium "Buildings.Media.Air" is not in the range 0..1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((noEvent(dataCenterContinuousTimeControl.cooCoi.ele[1].vol1.dynBal.medium.T >= 272.15)), dataCenterContinuousTimeControl.cooCoi.ele[1].vol1.dynBal.medium.T=-2846.517945869016) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.cooCoi.ele[1].vol1.dynBal.medium: Temperature T = -2846.52 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 226.101042 | | | | ((dataCenterContinuousTimeControl.cooCoi.dp2 <= dataCenterContinuousTimeControl.fan.dpMax), dataCenterContinuousTimeControl.cooCoi.dp2=18649956.41815008, dataCenterContinuousTimeControl.fan.dpMax=3000) --> "In DataCenterRenewables.dataCenterContinuousTimeControl.fan: Model operates with head -dp = 1.865e+07 Pa, | | | | exceeding the pressure allowed by the parameter DataCenterRenewables.dataCenterContinuousTimeControl.fan.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 1 warnings info: 3 errors