(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_DHC_Plants_Cooling_Subsystems_Examples_CoolingTowersParallel_OMSimulator-cs-euler_fmu --startTime=1.5552e+07 --stopTime=1.57248e+07 --stepSize=69.12 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_DHC_Plants_Cooling_Subsystems_Examples_CoolingTowersParallel_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersParallel (co-simulation) - fmiVersion: 2.0 - startTime : 15552000.000000 - stopTime : 15724800.000000 - tolerance : 1e-06 - stepSize : 69.12 warning: [fmi2Warning] CoolingTowersParallel/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27: The following assertion has been violated at time 15552000.000000 ((tow.dat.PFan_Q_flow_nominal >= -0.1 and tow.dat.PFan_Q_flow_nominal <= 0.0), tow.dat.PFan_Q_flow_nominal=-0.4126717746261882) --> "Variable violating min/max constraint: -0.1 <= tow.dat.PFan_Q_flow_nominal <= 0.0, has value: -0.412672" warning: [fmi2Warning] CoolingTowersParallel/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27: The following assertion has been violated at time 15552000.000000 ((tow.cooTow[2].dat.PFan_Q_flow_nominal >= -0.1 and tow.cooTow[2].dat.PFan_Q_flow_nominal <= 0.0), tow.cooTow[2].dat.PFan_Q_flow_nominal=-0.4126717746261882) --> "Variable violating min/max constraint: -0.1 <= tow.cooTow[2].dat.PFan_Q_flow_nominal <= 0.0, has value: -0.412672" warning: [fmi2Warning] CoolingTowersParallel/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27: The following assertion has been violated at time 15552000.000000 ((tow.cooTow[2].per.dat.PFan_Q_flow_nominal >= -0.1 and tow.cooTow[2].per.dat.PFan_Q_flow_nominal <= 0.0), tow.cooTow[2].per.dat.PFan_Q_flow_nominal=-0.4126717746261882) --> "Variable violating min/max constraint: -0.1 <= tow.cooTow[2].per.dat.PFan_Q_flow_nominal <= 0.0, has value: -0.412672" warning: [fmi2Warning] CoolingTowersParallel/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27: The following assertion has been violated at time 15552000.000000 ((tow.cooTow[1].dat.PFan_Q_flow_nominal >= -0.1 and tow.cooTow[1].dat.PFan_Q_flow_nominal <= 0.0), tow.cooTow[1].dat.PFan_Q_flow_nominal=-0.4126717746261882) --> "Variable violating min/max constraint: -0.1 <= tow.cooTow[1].dat.PFan_Q_flow_nominal <= 0.0, has value: -0.412672" warning: [fmi2Warning] CoolingTowersParallel/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27: The following assertion has been violated at time 15552000.000000 ((tow.cooTow[1].per.dat.PFan_Q_flow_nominal >= -0.1 and tow.cooTow[1].per.dat.PFan_Q_flow_nominal <= 0.0), tow.cooTow[1].per.dat.PFan_Q_flow_nominal=-0.4126717746261882) --> "Variable violating min/max constraint: -0.1 <= tow.cooTow[1].per.dat.PFan_Q_flow_nominal <= 0.0, has value: -0.412672" info: Result file: Buildings_13_Buildings_DHC_Plants_Cooling_Subsystems_Examples_CoolingTowersParallel_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter CoolingTowersParallel.weaDat.filNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 15553244.160000 | | | | ((noEvent(pum.vol.dynBal.medium.T <= 403.15)), pum.vol.dynBal.medium.T=455.2535309639869) --> "In CoolingTowersParallel.pum.vol.dynBal.medium: Temperature T = 455.254 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 15553244.160000 | | | | ((noEvent(pum.vol.dynBal.medium.T <= 403.15)), pum.vol.dynBal.medium.T=455.2535309639869) --> "In CoolingTowersParallel.pum.vol.dynBal.medium: Temperature T = 455.254 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 15553244.160000 | | | | ((noEvent(pum.vol.dynBal.medium.T <= 403.15)), pum.vol.dynBal.medium.T=455.2535309639869) --> "In CoolingTowersParallel.pum.vol.dynBal.medium: Temperature T = 455.254 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | error | No event found, but assert was triggered. Throwing now! error: [fmi2logger] [fmi2Error] CoolingTowersParallel/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:66: The following assertion has been violated at time 15553244.160000 ((noEvent(pum.vol.dynBal.medium.T <= 403.15)), pum.vol.dynBal.medium.T=455.2535309639869) --> "In CoolingTowersParallel.pum.vol.dynBal.medium: Temperature T = 455.254 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] CoolingTowersParallel/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "CoolingTowersParallel.root.CoolingTowersParallel" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 15553244.160000 | | | | ((noEvent(pum.vol.dynBal.medium.T <= 403.15)), pum.vol.dynBal.medium.T=455.2535309639869) --> "In CoolingTowersParallel.pum.vol.dynBal.medium: Temperature T = 455.254 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 5 warnings info: 3 errors