(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=345600 --stepSize=138.24 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 345600.000000 - tolerance : 1e-06 - stepSize : 138.24 warning: [fmi2Warning] AllElectricCWStorage/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101: The following assertion has been violated at time 0.000000 ((pla.pumChiWat.pum.etaHyd >= 0.0), pla.pumChiWat.pum.etaHyd=-5.539747996961011e-37) --> "Variable violating min constraint: 0.0 <= pla.pumChiWat.pum.etaHyd, has value: -5.53975e-37" warning: [fmi2Warning] AllElectricCWStorage/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101: The following assertion has been violated at time 0.000000 ((pla.pumHeaWat.pum.etaHyd >= 0.0), pla.pumHeaWat.pum.etaHyd=-2.229625178283091e-32) --> "Variable violating min constraint: 0.0 <= pla.pumHeaWat.pum.etaHyd, has value: -2.22963e-32" warning: [fmi2Warning] AllElectricCWStorage/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101: The following assertion has been violated at time 0.000000 ((pla.pumConWatCon.pum.etaHyd >= 0.0), pla.pumConWatCon.pum.etaHyd=-3.51358303712886e-41) --> "Variable violating min constraint: 0.0 <= pla.pumConWatCon.pum.etaHyd, has value: -3.51358e-41" warning: [fmi2Warning] AllElectricCWStorage/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101: The following assertion has been violated at time 0.000000 ((pla.pumConWatEva.pum.etaHyd >= 0.0), pla.pumConWatEva.pum.etaHyd=-7.662658219576064e-36) --> "Variable violating min constraint: 0.0 <= pla.pumConWatEva.pum.etaHyd, has value: -7.66266e-36" info: Result file: Buildings_13_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter AllElectricCWStorage.pla.heaPum.heaPum.aleMes.message will not be stored in the result file, because the signal type is not supported info: Parameter AllElectricCWStorage.weaDat.filNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | debug | Solving non-linear system 13285 failed at time=1382.4. | | | | For more information please use -lv LOG_NLS. error: [stepUntil] fmi2_doStep failed for FMU "AllElectricCWStorage.root.AllElectricCWStorage" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 4 warnings info: 1 errors