(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_DHC_Loads_Steam_Examples_BuildingTimeSeriesAtETS_OMSimulator-cs-euler_fmu --startTime=1.728e+06 --stopTime=1.8144e+06 --stepSize=34.56 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_DHC_Loads_Steam_Examples_BuildingTimeSeriesAtETS_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.DHC.Loads.Steam.Examples.BuildingTimeSeriesAtETS (co-simulation) - fmiVersion: 2.0 - startTime : 1728000.000000 - stopTime : 1814400.000000 - tolerance : 1e-06 - stepSize : 34.56 warning: [fmi2Warning] BuildingTimeSeriesAtETS/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Steam.mo:26: The following assertion has been violated at time 1728000.000000 ((bui.sta_a.T >= 1.0 and bui.sta_a.T <= 1e4), bui.sta_a.T=-906.8855539440865) --> "Variable violating min/max constraint: 1.0 <= bui.sta_a.T <= 1e4, has value: -906.886" info: Result file: Buildings_13_Buildings_DHC_Loads_Steam_Examples_BuildingTimeSeriesAtETS_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter BuildingTimeSeriesAtETS.bui.QHea.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter BuildingTimeSeriesAtETS.bui.fileName will not be stored in the result file, because the signal type is not supported info: Parameter BuildingTimeSeriesAtETS.bui.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:140:5-145:3:writable] | | | | The following assertion has been violated at time 1728103.680000 | | | | ((bui.steTra.m_flow > -9.211767247224383e-7), bui.steTra.m_flow=-0.01061195586890115) --> "In BuildingTimeSeriesAtETS.bui.pumCNR.vol: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 9.21177e-07 | | | | ports[1].m_flow = -0.010612 | | | | " LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortTransport.mo:80:3-81:70:writable] | | | | The following assertion has been violated at time 1728103.680000 | | | | ((bui.pumCNR.motSpe.y > -9.211767247224383e-7), bui.pumCNR.motSpe.y=-0.01061195586890115) --> "Reverting flow occurs even though allowFlowReversal is false" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortTransport.mo:80:3-81:70:writable] | | | | The following assertion has been violated at time 1728103.680000 | | | | ((bui.steTra.m_flow > (-bui.prv.ideSou.m_flow_small)), bui.steTra.m_flow=-0.01061195586890115, bui.prv.ideSou.m_flow_small=9.211767247224383e-07) --> "Reverting flow occurs even though allowFlowReversal is false" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortTransport.mo:80:3-81:70:writable] | | | | The following assertion has been violated at time 1728103.680000 | | | | ((bui.steTra.m_flow > (-bui.prv.ideSou.m_flow_small)), bui.steTra.m_flow=-0.01061195586890115, bui.prv.ideSou.m_flow_small=9.211767247224383e-07) --> "Reverting flow occurs even though allowFlowReversal is false" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortTransport.mo:80:3-81:70:writable] | | | | The following assertion has been violated at time 1728103.680000 | | | | ((bui.pumCNR.motSpe.y > -9.211767247224383e-7), bui.pumCNR.motSpe.y=-0.01061195586890115) --> "Reverting flow occurs even though allowFlowReversal is false" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:140:5-145:3:writable] | | | | The following assertion has been violated at time 1728103.680000 | | | | ((bui.steTra.m_flow > -9.211767247224383e-7), bui.steTra.m_flow=-0.01061195586890115) --> "In BuildingTimeSeriesAtETS.bui.pumCNR.vol: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 9.21177e-07 | | | | ports[1].m_flow = -0.010612 | | | | " LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortTransport.mo:80:3-81:70:writable] | | | | The following assertion has been violated at time 1728103.680000 | | | | ((bui.steTra.m_flow > (-bui.prv.ideSou.m_flow_small)), bui.steTra.m_flow=-0.01061195586890115, bui.prv.ideSou.m_flow_small=9.211767247224383e-07) --> "Reverting flow occurs even though allowFlowReversal is false" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortTransport.mo:80:3-81:70:writable] | | | | The following assertion has been violated at time 1728103.680000 | | | | ((bui.pumCNR.motSpe.y > -9.211767247224383e-7), bui.pumCNR.motSpe.y=-0.01061195586890115) --> "Reverting flow occurs even though allowFlowReversal is false" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:140:5-145:3:writable] | | | | The following assertion has been violated at time 1728103.680000 | | | | ((bui.steTra.m_flow > -9.211767247224383e-7), bui.steTra.m_flow=-0.01061195586890115) --> "In BuildingTimeSeriesAtETS.bui.pumCNR.vol: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 9.21177e-07 | | | | ports[1].m_flow = -0.010612 | | | | " LOG_ASSERT | error | No event found, but assert was triggered. Throwing now! error: [fmi2logger] [fmi2Error] BuildingTimeSeriesAtETS/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:140: The following assertion has been violated at time 1728103.680000 ((bui.steTra.m_flow > -9.211767247224383e-7), bui.steTra.m_flow=-0.01061195586890115) --> "In BuildingTimeSeriesAtETS.bui.pumCNR.vol: Model has flow reversal, but the parameter allowFlowReversal is set to false. m_flow_small = 9.21177e-07 ports[1].m_flow = -0.010612 error: [fmi2logger] [fmi2Error] BuildingTimeSeriesAtETS/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "BuildingTimeSeriesAtETS.root.BuildingTimeSeriesAtETS" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:140:5-145:3:writable] | | | | The following assertion has been violated at time 1728103.680000 | | | | ((bui.steTra.m_flow > -9.211767247224383e-7), bui.steTra.m_flow=-0.01061195586890115) --> "In BuildingTimeSeriesAtETS.bui.pumCNR.vol: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 9.21177e-07 | | | | ports[1].m_flow = -0.010612 | | | | " LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortTransport.mo:80:3-81:70:writable] | | | | The following assertion has been violated at time 1728103.680000 | | | | ((bui.pumCNR.motSpe.y > -9.211767247224383e-7), bui.pumCNR.motSpe.y=-0.01061195586890115) --> "Reverting flow occurs even though allowFlowReversal is false" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortTransport.mo:80:3-81:70:writable] | | | | The following assertion has been violated at time 1728103.680000 | | | | ((bui.steTra.m_flow > (-bui.prv.ideSou.m_flow_small)), bui.steTra.m_flow=-0.01061195586890115, bui.prv.ideSou.m_flow_small=9.211767247224383e-07) --> "Reverting flow occurs even though allowFlowReversal is false" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 1 warnings info: 3 errors