(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_DHC_Loads_Cooling_Examples_BuildingTimeSeriesWithETS_OMSimulator-cs-euler_fmu --startTime=2.592e+06 --stopTime=3.6288e+06 --stepSize=414.72 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_DHC_Loads_Cooling_Examples_BuildingTimeSeriesWithETS_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.DHC.Loads.Cooling.Examples.BuildingTimeSeriesWithETS (co-simulation) - fmiVersion: 2.0 - startTime : 2592000.000000 - stopTime : 3628800.000000 - tolerance : 1e-06 - stepSize : 414.72 warning: [fmi2Warning] BuildingTimeSeriesWithETS/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x) not in the resources directory. The FMU might not work as expected if you send it to a different system warning: [fmi2Warning] BuildingTimeSeriesWithETS/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos" warning: [fmi2Warning] BuildingTimeSeriesWithETS/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/BaseClasses/WetCoilUARated.mo:137: The following assertion has been violated during initialization at time 2592000.000000 ((buiWitETS.bui.terUniCoo.hexWetNtu.UAFroRated.isFulDry or buiWitETS.bui.terUniCoo.hexWetNtu.UAFroRated.isFulWet), buiWitETS.bui.terUniCoo.hexWetNtu.UAFroRated.isFulDry=false, buiWitETS.bui.terUniCoo.hexWetNtu.UAFroRated.isFulWet=false) --> "In BuildingTimeSeriesWithETS.buiWitETS.bui.terUniCoo.hexWetNtu.UAFroRated: The nominal conditions correspond to a partially-wet coil regime. The modeling uncertainty under such conditions has not been assessed. Rather specify nominal conditions in fully-dry or fully-wet regime." info: Result file: Buildings_13_Buildings_DHC_Loads_Cooling_Examples_BuildingTimeSeriesWithETS_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable BuildingTimeSeriesWithETS.buiWitETS.bui.filNam will not be stored in the result file, because the signal type is not supported info: Parameter BuildingTimeSeriesWithETS.buiWitETS.bui.loa.delimiter will not be stored in the result file, because the signal type is not supported info: Variable BuildingTimeSeriesWithETS.buiWitETS.bui.loa.tableName will not be stored in the result file, because the signal type is not supported info: Variable BuildingTimeSeriesWithETS.buiWitETS.filNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_13_Buildings.DHC.Loads.Cooling.Examples.BuildingTimeSeriesWithETS/534.fmutmp/sources/Buildings_13_Buildings_DHC_Loads_Cooling_Examples_BuildingTimeSeriesWithETS_functions.c:4353: Invalid root: (-53.3143)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_13_Buildings.DHC.Loads.Cooling.Examples.BuildingTimeSeriesWithETS/534.fmutmp/sources/Buildings_13_Buildings_DHC_Loads_Cooling_Examples_BuildingTimeSeriesWithETS_functions.c:4363: Invalid root: (-53.3143)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_13_Buildings.DHC.Loads.Cooling.Examples.BuildingTimeSeriesWithETS/534.fmutmp/sources/Buildings_13_Buildings_DHC_Loads_Cooling_Examples_BuildingTimeSeriesWithETS_functions.c:4402: Invalid root: (-53.3143)^(-1.25) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_13_Buildings.DHC.Loads.Cooling.Examples.BuildingTimeSeriesWithETS/534.fmutmp/sources/Buildings_13_Buildings_DHC_Loads_Cooling_Examples_BuildingTimeSeriesWithETS_functions.c:4412: Invalid root: (-53.3143)^(-1.25) error: [stepUntil] fmi2_doStep failed for FMU "BuildingTimeSeriesWithETS.root.BuildingTimeSeriesWithETS" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 3 warnings info: 1 errors