(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_DHC_ETS_Combined_Examples_HeatRecoveryHeatPump_OMSimulator-cs-euler_fmu --startTime=6.5e+06 --stopTime=7e+06 --stepSize=200 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_DHC_ETS_Combined_Examples_HeatRecoveryHeatPump_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.DHC.ETS.Combined.Examples.HeatRecoveryHeatPump (co-simulation) - fmiVersion: 2.0 - startTime : 6500000.000000 - stopTime : 7000000.000000 - tolerance : 1e-06 - stepSize : 200 warning: [fmi2Warning] HeatRecoveryHeatPump/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos" warning: [fmi2Warning] HeatRecoveryHeatPump/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311: The following assertion has been violated at time 6500000.000000 ((ets.heaPum.pumCon.eff.yMot >= 0.0), ets.heaPum.pumCon.eff.yMot=-1.260524396470191e-14) --> "Variable violating min constraint: 0.0 <= ets.heaPum.pumCon.eff.yMot, has value: -1.26052e-14" warning: [fmi2Warning] HeatRecoveryHeatPump/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311: The following assertion has been violated at time 6500000.000000 ((ets.heaPum.pumEva.eff.yMot >= 0.0), ets.heaPum.pumEva.eff.yMot=-9.478815781884221e-15) --> "Variable violating min constraint: 0.0 <= ets.heaPum.pumEva.eff.yMot, has value: -9.47882e-15" info: Result file: Buildings_13_Buildings_DHC_ETS_Combined_Examples_HeatRecoveryHeatPump_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter HeatRecoveryHeatPump.TDisWatSup.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter HeatRecoveryHeatPump.TDisWatSup.fileName will not be stored in the result file, because the signal type is not supported info: Parameter HeatRecoveryHeatPump.TDisWatSup.tableName will not be stored in the result file, because the signal type is not supported info: Parameter HeatRecoveryHeatPump.datHeaPum.datHea.devIde will not be stored in the result file, because the signal type is not supported info: Variable HeatRecoveryHeatPump.datHeaPum.datHeaSca.devIde will not be stored in the result file, because the signal type is not supported info: Variable HeatRecoveryHeatPump.ets.datHeaPum.datHeaSca.devIde will not be stored in the result file, because the signal type is not supported info: Variable HeatRecoveryHeatPump.ets.heaPum.dat.datHeaSca.devIde will not be stored in the result file, because the signal type is not supported info: Variable HeatRecoveryHeatPump.ets.heaPum.heaPum.refCyc.refCycHeaPumCoo.devIde will not be stored in the result file, because the signal type is not supported info: Variable HeatRecoveryHeatPump.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.datTab.devIde will not be stored in the result file, because the signal type is not supported info: Variable HeatRecoveryHeatPump.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.devIde will not be stored in the result file, because the signal type is not supported info: Variable HeatRecoveryHeatPump.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabPEle.delimiter will not be stored in the result file, because the signal type is not supported info: Variable HeatRecoveryHeatPump.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabPEle.fileName will not be stored in the result file, because the signal type is not supported info: Variable HeatRecoveryHeatPump.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabPEle.tableName will not be stored in the result file, because the signal type is not supported info: Variable HeatRecoveryHeatPump.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabQUse_flow.delimiter will not be stored in the result file, because the signal type is not supported info: Variable HeatRecoveryHeatPump.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabQUse_flow.fileName will not be stored in the result file, because the signal type is not supported info: Variable HeatRecoveryHeatPump.ets.heaPum.heaPum.refCyc.refCycHeaPumHea.tabQUse_flow.tableName will not be stored in the result file, because the signal type is not supported info: Parameter HeatRecoveryHeatPump.filNam will not be stored in the result file, because the signal type is not supported info: Parameter HeatRecoveryHeatPump.loa.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter HeatRecoveryHeatPump.loa.tableName will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] HeatRecoveryHeatPump/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:66: The following assertion has been violated at time 6500105.000000 ((noEvent(ets.junHeaWat.vol.dynBal.medium.T <= 403.15)), ets.junHeaWat.vol.dynBal.medium.T=1985.900612802215) --> "In HeatRecoveryHeatPump.ets.junHeaWat.vol.dynBal.medium: Temperature T = 1985.9 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] HeatRecoveryHeatPump/logFmi2Call: fmi2DoStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "HeatRecoveryHeatPump.root.HeatRecoveryHeatPump" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 6500105.000000 | | | | ((noEvent(ets.junHeaWat.vol.dynBal.medium.T <= 403.15)), ets.junHeaWat.vol.dynBal.medium.T=1985.90061280808) --> "In HeatRecoveryHeatPump.ets.junHeaWat.vol.dynBal.medium: Temperature T = 1985.9 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 6500105.000000 | | | | ((noEvent(ets.junChiWat.vol.dynBal.medium.T >= 272.15)), ets.junChiWat.vol.dynBal.medium.T=-1092.952988093734) --> "In HeatRecoveryHeatPump.ets.junChiWat.vol.dynBal.medium: Temperature T = -1092.95 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 6500105.000000 | | | | ((noEvent(ets.colAmbWat.con[1].junConRet.vol.dynBal.medium.T >= 272.15)), ets.colAmbWat.con[1].junConRet.vol.dynBal.medium.T=234.4960007621762) --> "In HeatRecoveryHeatPump.ets.colAmbWat.con[1].junConRet.vol.dynBal.medium: Temperature T = 234.496 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 6500105.000000 | | | | ((noEvent(ets.tanHeaWat.junBot.vol.dynBal.medium.T >= 272.15)), ets.tanHeaWat.junBot.vol.dynBal.medium.T=254.5203528598395) --> "In HeatRecoveryHeatPump.ets.tanHeaWat.junBot.vol.dynBal.medium: Temperature T = 254.52 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 6500105.000000 | | | | (((-ets.heaPum.pumEva.dp) <= ets.heaPum.pumEva.dpMax), ets.heaPum.pumEva.dp=-632857.1399866024, ets.heaPum.pumEva.dpMax=310000) --> "In HeatRecoveryHeatPump.ets.heaPum.pumEva: Model operates with head -dp = 632857 Pa, | | | | exceeding the pressure allowed by the parameter HeatRecoveryHeatPump.ets.heaPum.pumEva.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 6500105.000000 | | | | (((-ets.heaPum.pumCon.dp) <= ets.heaPum.pumCon.dpMax), ets.heaPum.pumCon.dp=-632857.1399556478, ets.heaPum.pumCon.dpMax=310000) --> "In HeatRecoveryHeatPump.ets.heaPum.pumCon: Model operates with head -dp = 632857 Pa, | | | | exceeding the pressure allowed by the parameter HeatRecoveryHeatPump.ets.heaPum.pumCon.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:69:5-69:152:writable] | | | | The following assertion has been violated at time 6500105.000000 | | | | ((noEvent(ets.heaPum.heaPum.sta_b2.p >= 0.0)), ets.heaPum.heaPum.sta_b2.p=-334621.6062289914) --> "Pressure (= -334622 Pa) of medium "Buildings.Media.Water" is negative | | | | (Temperature = 260.86 K)" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 6500105.000000 | | | | ((noEvent(ets.heaPum.heaPum.eva.vol.dynBal.medium.T >= 272.15)), ets.heaPum.heaPum.eva.vol.dynBal.medium.T=260.8604617876198) --> "In HeatRecoveryHeatPump.ets.heaPum.heaPum.eva.vol.dynBal.medium: Temperature T = 260.86 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 3 warnings info: 3 errors