(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.RadiantHeatingCooling_TRoom_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_RadiantHeatingCooling_TRoom_OMSimulator-cs-euler_fmu --startTime=7.776e+06 --stopTime=9.504e+06 --stepSize=273.029 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_RadiantHeatingCooling_TRoom_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.RadiantHeatingCooling_TRoom (co-simulation) - fmiVersion: 2.0 - startTime : 7776000.000000 - stopTime : 9504000.000000 - tolerance : 1e-06 - stepSize : 273.029 EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.17 06:53 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 04/01/2006 for SPAWN-RUNPERIOD warning: [fmi2Warning] RadiantHeatingCooling_TRoom/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20: The following assertion has been violated at time 7776000.000000 ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5), duc.m_flow=-6.593472789973019e-15) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" info: Result file: ../Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.RadiantHeatingCooling_TRoom_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter RadiantHeatingCooling_TRoom.attFlo.surfaceName will not be stored in the result file, because the signal type is not supported info: Parameter RadiantHeatingCooling_TRoom.building.epwName will not be stored in the result file, because the signal type is not supported info: Parameter RadiantHeatingCooling_TRoom.building.idfName will not be stored in the result file, because the signal type is not supported info: Parameter RadiantHeatingCooling_TRoom.building.weaName will not be stored in the result file, because the signal type is not supported info: Parameter RadiantHeatingCooling_TRoom.livFlo.surfaceName will not be stored in the result file, because the signal type is not supported info: Parameter RadiantHeatingCooling_TRoom.zon.zoneName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Interfaces/PrescribedOutlet.mo:322:5-323:70:writable] | | | | The following assertion has been violated at time 7776819.087000 | | | | ((slaFlo.m_flow > (-hea.outCon.m_flow_small)), slaFlo.m_flow=-0.04119186409901974, hea.outCon.m_flow_small=1.904761904761905e-05) --> "Reverting flow occurs even though allowFlowReversal is false" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:140:5-145:3:writable] | | | | The following assertion has been violated at time 7776819.087000 | | | | ((slaFlo.sla.m_flow > -6.349206349206348e-6), slaFlo.sla.m_flow=-0.01373062136633991) --> "In RadiantHeatingCooling_TRoom.slaFlo.sla.vol[1]: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 6.34921e-06 | | | | ports[1].m_flow = -0.0137306 | | | | " LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 7776819.087000 | | | | ((noEvent(slaFlo.sla.vol[1].dynBal.medium.T <= 403.15)), slaFlo.sla.vol[1].dynBal.medium.T=456.8956415157553) --> "In RadiantHeatingCooling_TRoom.slaFlo.sla.vol[1].dynBal.medium: Temperature T = 456.896 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 7776819.087000 | | | | ((noEvent(slaFlo.sla.vol[1].dynBal.medium.T <= 403.15)), slaFlo.sla.vol[1].dynBal.medium.T=456.8956415157553) --> "In RadiantHeatingCooling_TRoom.slaFlo.sla.vol[1].dynBal.medium: Temperature T = 456.896 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:140:5-145:3:writable] | | | | The following assertion has been violated at time 7776819.087000 | | | | ((slaFlo.sla.m_flow > -6.349206349206348e-6), slaFlo.sla.m_flow=-0.01373062136633991) --> "In RadiantHeatingCooling_TRoom.slaFlo.sla.vol[1]: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 6.34921e-06 | | | | ports[1].m_flow = -0.0137306 | | | | " LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Interfaces/PrescribedOutlet.mo:322:5-323:70:writable] | | | | The following assertion has been violated at time 7776819.087000 | | | | ((slaFlo.m_flow > (-hea.outCon.m_flow_small)), slaFlo.m_flow=-0.04119186409901974, hea.outCon.m_flow_small=1.904761904761905e-05) --> "Reverting flow occurs even though allowFlowReversal is false" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 7776819.087000 | | | | ((noEvent(slaFlo.sla.vol[1].dynBal.medium.T <= 403.15)), slaFlo.sla.vol[1].dynBal.medium.T=456.8956415157553) --> "In RadiantHeatingCooling_TRoom.slaFlo.sla.vol[1].dynBal.medium: Temperature T = 456.896 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:140:5-145:3:writable] | | | | The following assertion has been violated at time 7776819.087000 | | | | ((slaFlo.sla.m_flow > -6.349206349206348e-6), slaFlo.sla.m_flow=-0.01373062136633991) --> "In RadiantHeatingCooling_TRoom.slaFlo.sla.vol[1]: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 6.34921e-06 | | | | ports[1].m_flow = -0.0137306 | | | | " LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Interfaces/PrescribedOutlet.mo:322:5-323:70:writable] | | | | The following assertion has been violated at time 7776819.087000 | | | | ((slaFlo.m_flow > (-hea.outCon.m_flow_small)), slaFlo.m_flow=-0.04119186409901974, hea.outCon.m_flow_small=1.904761904761905e-05) --> "Reverting flow occurs even though allowFlowReversal is false" LOG_ASSERT | error | No event found, but assert was triggered. Throwing now! error: [fmi2logger] [fmi2Error] RadiantHeatingCooling_TRoom/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Interfaces/PrescribedOutlet.mo:322: The following assertion has been violated at time 7776819.087000 ((slaFlo.m_flow > (-hea.outCon.m_flow_small)), slaFlo.m_flow=-0.04119186409901974, hea.outCon.m_flow_small=1.904761904761905e-05) --> "Reverting flow occurs even though allowFlowReversal is false" error: [fmi2logger] [fmi2Error] RadiantHeatingCooling_TRoom/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "RadiantHeatingCooling_TRoom.root.RadiantHeatingCooling_TRoom" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Interfaces/PrescribedOutlet.mo:322:5-323:70:writable] | | | | The following assertion has been violated at time 7776819.087000 | | | | ((slaFlo.m_flow > (-hea.outCon.m_flow_small)), slaFlo.m_flow=-0.04119186409901974, hea.outCon.m_flow_small=1.904761904761905e-05) --> "Reverting flow occurs even though allowFlowReversal is false" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:140:5-145:3:writable] | | | | The following assertion has been violated at time 7776819.087000 | | | | ((slaFlo.sla.m_flow > -6.349206349206348e-6), slaFlo.sla.m_flow=-0.01373062136633991) --> "In RadiantHeatingCooling_TRoom.slaFlo.sla.vol[1]: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 6.34921e-06 | | | | ports[1].m_flow = -0.0137306 | | | | " LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 7776819.087000 | | | | ((noEvent(slaFlo.sla.vol[1].dynBal.medium.T <= 403.15)), slaFlo.sla.vol[1].dynBal.medium.T=456.8956415157553) --> "In RadiantHeatingCooling_TRoom.slaFlo.sla.vol[1].dynBal.medium: Temperature T = 456.896 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 917, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error terminate called without an active exception Aborted (core dumped)