(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_12_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_12_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_ClosedLoop_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=2400 --stepSize=0.96 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_12_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_ClosedLoop_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 2400.000000 - tolerance : 1e-06 - stepSize : 0.96 info: Result file: ../Buildings_12_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable CoolingCoilHumidifyingHeating_ClosedLoop.masFra.substanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:364:5-373:38:writable] | | | | The following assertion has been violated at time 2.880000 | | | | ((noEvent(ahu.m1_flow > (-0.1) * ahu.cooCoi.m1_flow_nominal) and noEvent(ahu.m2_flow > (-0.1) * ahu.cooCoi.m2_flow_nominal)), ahu.m1_flow=11.83920042345203, ahu.cooCoi.m1_flow_nominal=2.9, ahu.m2_flow=-14.16098180486219, ahu.cooCoi.m2_flow_nominal=3.3) --> "*** Warning in CoolingCoilHumidifyingHeating_ClosedLoop.ahu.cooCoi: The flow direction reversed. | | | | However, because the constant use_dynamicFlowRegime is set to false, | | | | the model does not change equations based on the actual flow regime. | | | | To switch equations based on the actual flow regime during the simulation, | | | | set the constant use_dynamicFlowRegime=true. | | | | Note that this can lead to slow simulation because of events." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 4.800000 | | | | ((noEvent(ahu.fan.vol.dynBal.medium.T <= 423.15)), ahu.fan.vol.dynBal.medium.T=967.6925970963877) --> "In CoolingCoilHumidifyingHeating_ClosedLoop.ahu.fan.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 4.800000 | | | | ((noEvent(ahu.fan.vol.dynBal.medium.T <= 423.15)), ahu.fan.vol.dynBal.medium.T=967.6925970963877) --> "In CoolingCoilHumidifyingHeating_ClosedLoop.ahu.fan.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 4.800000 | | | | ((noEvent(ahu.fan.vol.dynBal.medium.T <= 423.15)), ahu.fan.vol.dynBal.medium.T=967.6925970963877) --> "In CoolingCoilHumidifyingHeating_ClosedLoop.ahu.fan.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." LOG_ASSERT | error | No event found, but assert was triggered. Throwing now! error: [fmi2logger] [fmi2Error] CoolingCoilHumidifyingHeating_ClosedLoop/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:364: The following assertion has been violated at time 2.880000 ((noEvent(ahu.m1_flow > (-0.1) * ahu.cooCoi.m1_flow_nominal) and noEvent(ahu.m2_flow > (-0.1) * ahu.cooCoi.m2_flow_nominal)), ahu.m1_flow=11.83920042345203, ahu.cooCoi.m1_flow_nominal=2.9, ahu.m2_flow=-14.16098180486219, ahu.cooCoi.m2_flow_nominal=3.3) --> "*** Warning in CoolingCoilHumidifyingHeating_ClosedLoop.ahu.cooCoi: The flow direction reversed. However, because the constant use_dynamicFlowRegime is set to false, the model does not change equations based on the actual flow regime. To switch equations based on the actual flow regime during the simulation, set the constant use_dynamicFlowRegime=true. Note that this can lead to slow simulation because of events." error: [fmi2logger] [fmi2Error] CoolingCoilHumidifyingHeating_ClosedLoop/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "CoolingCoilHumidifyingHeating_ClosedLoop.root.CoolingCoilHumidifyingHeating_ClosedLoop" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 4.800000 | | | | ((noEvent(ahu.fan.vol.dynBal.medium.T <= 423.15)), ahu.fan.vol.dynBal.medium.T=967.6925970963877) --> "In CoolingCoilHumidifyingHeating_ClosedLoop.ahu.fan.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 3 errors