(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildSysPro_BuildSysPro_IBPSA_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=604800 --stepSize=60 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildSysPro_BuildSysPro_IBPSA_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : BuildSysPro.IBPSA.ThermalZones.ReducedOrder.Validation.RoomWithoutLatentGain (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 604800.000000 - tolerance : 1e-06 - stepSize : 60 warning: [fmi2Warning] RoomWithoutLatentGain/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28: The following assertion has been violated during initialization at time 0.000000 ((not senRelHum.warnAboutOnePortConnection), senRelHum.warnAboutOnePortConnection=true) --> "Sensor RoomWithoutLatentGain.senRelHum can lead to numerical problems if connected to a scalar fluid port. Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`. See IBPSA.Fluid.Sensors.UsersGuide for more information. To disable this warning, set 'warnAboutOnePortConnection = false' in RoomWithoutLatentGain.senRelHum." warning: [fmi2Warning] RoomWithoutLatentGain/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28: The following assertion has been violated during initialization at time 0.000000 ((not senMasFra.warnAboutOnePortConnection), senMasFra.warnAboutOnePortConnection=true) --> "Sensor RoomWithoutLatentGain.senMasFra can lead to numerical problems if connected to a scalar fluid port. Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`. See IBPSA.Fluid.Sensors.UsersGuide for more information. To disable this warning, set 'warnAboutOnePortConnection = false' in RoomWithoutLatentGain.senMasFra." info: Result file: BuildSysPro_BuildSysPro_IBPSA_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter RoomWithoutLatentGain.assEqu.message will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.intGai.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.intGai.fileName will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.intGai.tableName will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.outdoorTemp.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.outdoorTemp.fileName will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.outdoorTemp.tableName will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.reference.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.reference.fileName will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.reference.tableName will not be stored in the result file, because the signal type is not supported info: Variable RoomWithoutLatentGain.senMasFra.substanceName will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.tableSolRadWindow.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.tableSolRadWindow.fileName will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.tableSolRadWindow.tableName will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.ventRate.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.ventRate.fileName will not be stored in the result file, because the signal type is not supported info: Parameter RoomWithoutLatentGain.ventRate.tableName will not be stored in the result file, because the signal type is not supported info: 2 warnings info: 0 errors