(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_PowerEuler_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=200 --stepSize=0.08 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_PowerEuler_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : BuildSysPro.IBPSA.Fluid.Movers.Validation.PowerEuler (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 200.000000 - tolerance : 1e-06 - stepSize : 0.08 warning: [fmi2Warning] PowerEuler/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387: The following assertion has been violated during initialization at time 0.000000 ((pump_dp.nominalValuesDefineDefaultPressureCurve), pump_dp.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning: You are using a flow or pressure controlled mover with the default pressure curve. This leads to approximate calculations of the electrical power consumption. Add the correct pressure curve in the record per to obtain an accurate computation. Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." warning: [fmi2Warning] PowerEuler/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420: The following assertion has been violated during initialization at time 0.000000 ((not (pump_dp.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump_dp.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in PowerEuler.pump_dp: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. This requires that per.pressure be provided. Because it is not, the model will override this setting and use .NotProvided instead." warning: [fmi2Warning] PowerEuler/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387: The following assertion has been violated during initialization at time 0.000000 ((pump_m_flow.nominalValuesDefineDefaultPressureCurve), pump_m_flow.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning: You are using a flow or pressure controlled mover with the default pressure curve. This leads to approximate calculations of the electrical power consumption. Add the correct pressure curve in the record per to obtain an accurate computation. Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." warning: [fmi2Warning] PowerEuler/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420: The following assertion has been violated during initialization at time 0.000000 ((not (pump_m_flow.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump_m_flow.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in PowerEuler.pump_m_flow: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. This requires that per.pressure be provided. Because it is not, the model will override this setting and use .NotProvided instead." info: Result file: BuildSysPro_BuildSysPro_IBPSA_Fluid_Movers_Validation_PowerEuler_OMSimulator-cs-euler_res.mat (bufferSize=10) info: 4 warnings info: 0 errors