(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_ThermalZones_ReducedOrder_Examples_MultizoneMoistAirCO2_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=3.1536e+07 --stepSize=3600 --mode=cs --timeout=240 --tolerance=1e-06 ../AixLib_AixLib_ThermalZones_ReducedOrder_Examples_MultizoneMoistAirCO2_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : AixLib.ThermalZones.ReducedOrder.Examples.MultizoneMoistAirCO2 (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 31536000.000000 - tolerance : 1e-06 - stepSize : 3600 LOG_STDOUT | info | ... loading "Internals" from "/tmp/tmp8yjs_vm9/MultizoneMoistAirCO2-zr3ti4q8/temp/0001_MultizoneMoistAirCO2/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/LowOrder_ExampleData/Internals_Input_6Zone_SIA.txt" info: Result file: AixLib_AixLib_ThermalZones_ReducedOrder_Examples_MultizoneMoistAirCO2_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter MultizoneMoistAirCO2.multizone.zoneParam[1].TSoiFil will not be stored in the result file, because the signal type is not supported info: Parameter MultizoneMoistAirCO2.multizone.zoneParam[2].TSoiFil will not be stored in the result file, because the signal type is not supported info: Parameter MultizoneMoistAirCO2.multizone.zoneParam[3].TSoiFil will not be stored in the result file, because the signal type is not supported info: Parameter MultizoneMoistAirCO2.multizone.zoneParam[4].TSoiFil will not be stored in the result file, because the signal type is not supported info: Parameter MultizoneMoistAirCO2.multizone.zoneParam[5].TSoiFil will not be stored in the result file, because the signal type is not supported info: Parameter MultizoneMoistAirCO2.tableInternalGains.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter MultizoneMoistAirCO2.tableInternalGains.fileName will not be stored in the result file, because the signal type is not supported info: Parameter MultizoneMoistAirCO2.tableInternalGains.tableName will not be stored in the result file, because the signal type is not supported info: Parameter MultizoneMoistAirCO2.weaDat.filNam will not be stored in the result file, because the signal type is not supported error: [getReal] getReal returned +/-inf error: [updateSignals] failed to fetch variable multizone.zone[5].heaterCooler.pITempHeat.PI.gainTrack.u LOG_ASSERT | debug | division leads to inf or nan at time 136800, (a=nan) / (b=8040), where divisor b is: multizone.zone[1].ROM.volMoiAir.dynBal.m error: [stepUntil] fmi2_doStep failed for FMU "MultizoneMoistAirCO2.root.MultizoneMoistAirCO2" error: [getReal] getReal returned NAN error: [updateSignals] failed to fetch variable multizone.zone[5].heaterCooler.pITempHeat.y Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 5 errors