(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_ThermalZones_HighOrder_Examples_RoomGFOw2_DayNightMode_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=86400 --stepSize=60 --mode=cs --timeout=240 --tolerance=1e-06 ../AixLib_AixLib_ThermalZones_HighOrder_Examples_RoomGFOw2_DayNightMode_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : AixLib.ThermalZones.HighOrder.Examples.RoomGFOw2_DayNightMode (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 86400.000000 - tolerance : 1e-06 - stepSize : 60 warning: [fmi2Warning] RoomGFOw2_DayNightMode/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1) not in the resources directory. The FMU might not work as expected if you send it to a different system info: Result file: AixLib_AixLib_ThermalZones_HighOrder_Examples_RoomGFOw2_DayNightMode_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter RoomGFOw2_DayNightMode.Pump.table_minMaxCharacteristics.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter RoomGFOw2_DayNightMode.Pump.table_minMaxCharacteristics.fileName will not be stored in the result file, because the signal type is not supported info: Parameter RoomGFOw2_DayNightMode.Pump.table_minMaxCharacteristics.tableName will not be stored in the result file, because the signal type is not supported info: Parameter RoomGFOw2_DayNightMode.combinedWeather.SOD.name[1] will not be stored in the result file, because the signal type is not supported info: Parameter RoomGFOw2_DayNightMode.combinedWeather.SOD.name[2] will not be stored in the result file, because the signal type is not supported info: Parameter RoomGFOw2_DayNightMode.combinedWeather.SOD.name[3] will not be stored in the result file, because the signal type is not supported info: Parameter RoomGFOw2_DayNightMode.combinedWeather.SOD.name[4] will not be stored in the result file, because the signal type is not supported info: Parameter RoomGFOw2_DayNightMode.combinedWeather.SOD.name[5] will not be stored in the result file, because the signal type is not supported info: Parameter RoomGFOw2_DayNightMode.combinedWeather.WeatherData.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter RoomGFOw2_DayNightMode.combinedWeather.fileName will not be stored in the result file, because the signal type is not supported info: Parameter RoomGFOw2_DayNightMode.combinedWeather.formatTRY will not be stored in the result file, because the signal type is not supported info: Parameter RoomGFOw2_DayNightMode.combinedWeather.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Media/Water.mo:66:5-67:119:writable] | | | | The following assertion has been violated at time 60.000000 | | | | ((noEvent(radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium.T <= 403.15)), radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium.T=961.5335708068104) --> "In RoomGFOw2_DayNightMode.radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium: Temperature T = 961.534 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "AixLib.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Media/Water.mo:66:5-67:119:writable] | | | | The following assertion has been violated at time 60.000000 | | | | ((noEvent(radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium.T <= 403.15)), radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium.T=961.5335708068104) --> "In RoomGFOw2_DayNightMode.radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium: Temperature T = 961.534 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "AixLib.Media.Water"." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Media/Water.mo:66:5-67:119:writable] | | | | The following assertion has been violated at time 60.000000 | | | | ((noEvent(radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium.T <= 403.15)), radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium.T=961.5335708068104) --> "In RoomGFOw2_DayNightMode.radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium: Temperature T = 961.534 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "AixLib.Media.Water"." LOG_ASSERT | error | No event found, but assert was triggered. Throwing now! error: [fmi2logger] [fmi2Error] RoomGFOw2_DayNightMode/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Media/Water.mo:66: The following assertion has been violated at time 60.000000 ((noEvent(radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium.T <= 403.15)), radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium.T=961.5335708068104) --> "In RoomGFOw2_DayNightMode.radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium: Temperature T = 961.534 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "AixLib.Media.Water"." error: [fmi2logger] [fmi2Error] RoomGFOw2_DayNightMode/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "RoomGFOw2_DayNightMode.root.RoomGFOw2_DayNightMode" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Media/Water.mo:66:5-67:119:writable] | | | | The following assertion has been violated at time 60.000000 | | | | ((noEvent(radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium.T <= 403.15)), radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium.T=961.5335708068104) --> "In RoomGFOw2_DayNightMode.radiator_ML_delta.multiLayer_HE[1].Volume.dynBal.medium: Temperature T = 961.534 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "AixLib.Media.Water"." Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 1 warnings info: 3 errors