(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_Systems_ModularAHU_Examples_EONERC_AHU2_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=7200 --stepSize=15 --mode=cs --timeout=240 --tolerance=1e-06 ../AixLib_AixLib_Systems_ModularAHU_Examples_EONERC_AHU2_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : AixLib.Systems.ModularAHU.Examples.EONERC_AHU2 (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 7200.000000 - tolerance : 1e-06 - stepSize : 15 warning: [fmi2Warning] EONERC_AHU2/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391: The following assertion has been violated during initialization at time 0.000000 ((genericAHU.fanSup.nominalValuesDefineDefaultPressureCurve), genericAHU.fanSup.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in EONERC_AHU2.genericAHU.fanSup: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." warning: [fmi2Warning] EONERC_AHU2/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391: The following assertion has been violated during initialization at time 0.000000 ((genericAHU.fanRet.nominalValuesDefineDefaultPressureCurve), genericAHU.fanRet.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in EONERC_AHU2.genericAHU.fanRet: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." info: Result file: AixLib_AixLib_Systems_ModularAHU_Examples_EONERC_AHU2_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter EONERC_AHU2.genericAHU.cooler.hydraulicModule.PumpInterface.physics.maxMinTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter EONERC_AHU2.genericAHU.cooler.hydraulicModule.PumpInterface.physics.maxMinTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter EONERC_AHU2.genericAHU.cooler.hydraulicModule.PumpInterface.physics.maxMinTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.cooler.hydraulicModule.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.cooler.hydraulicModule.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.cooler.hydraulicModule.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.cooler.hydraulicModule.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.cooler.hydraulicModule.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.cooler.hydraulicModule.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.cooler.hydraulicModule.pipeModel will not be stored in the result file, because the signal type is not supported info: Parameter EONERC_AHU2.genericAHU.cooler.hydraulicModuleIcon will not be stored in the result file, because the signal type is not supported info: Parameter EONERC_AHU2.genericAHU.heater.hydraulicModule.PumpInterface.physics.maxMinTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter EONERC_AHU2.genericAHU.heater.hydraulicModule.PumpInterface.physics.maxMinTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter EONERC_AHU2.genericAHU.heater.hydraulicModule.PumpInterface.physics.maxMinTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.heater.hydraulicModule.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.heater.hydraulicModule.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.heater.hydraulicModule.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.heater.hydraulicModule.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.heater.hydraulicModule.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.heater.hydraulicModule.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.heater.hydraulicModule.pipeModel will not be stored in the result file, because the signal type is not supported info: Parameter EONERC_AHU2.genericAHU.heater.hydraulicModuleIcon will not be stored in the result file, because the signal type is not supported info: Parameter EONERC_AHU2.genericAHU.preheater.hydraulicModule.PumpInterface.physics.maxMinTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter EONERC_AHU2.genericAHU.preheater.hydraulicModule.PumpInterface.physics.maxMinTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter EONERC_AHU2.genericAHU.preheater.hydraulicModule.PumpInterface.physics.maxMinTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.preheater.hydraulicModule.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.preheater.hydraulicModule.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.preheater.hydraulicModule.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.preheater.hydraulicModule.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.preheater.hydraulicModule.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.preheater.hydraulicModule.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable EONERC_AHU2.genericAHU.preheater.hydraulicModule.pipeModel will not be stored in the result file, because the signal type is not supported info: Parameter EONERC_AHU2.genericAHU.preheater.hydraulicModuleIcon will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] EONERC_AHU2/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Media/Water.mo:63: The following assertion has been violated at time 0.811726 ((noEvent(genericAHU.cooler.hydraulicModule.pipe4.plugFlowPipe.vol_a.dynBal.medium.T >= 272.15)), genericAHU.cooler.hydraulicModule.pipe4.plugFlowPipe.vol_a.dynBal.medium.T=262.3500607050153) --> "In EONERC_AHU2.genericAHU.cooler.hydraulicModule.pipe4.plugFlowPipe.vol_a.dynBal.medium: Temperature T = 262.35 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "AixLib.Media.Water"." error: [fmi2logger] [fmi2Error] EONERC_AHU2/logFmi2Call: fmi2DoStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "EONERC_AHU2.root.EONERC_AHU2" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Media/Water.mo:63:5-64:119:writable] | | | | The following assertion has been violated at time 0.811726 | | | | ((noEvent(genericAHU.cooler.hydraulicModule.pipe4.plugFlowPipe.vol_a.dynBal.medium.T >= 272.15)), genericAHU.cooler.hydraulicModule.pipe4.plugFlowPipe.vol_a.dynBal.medium.T=262.350060704743) --> "In EONERC_AHU2.genericAHU.cooler.hydraulicModule.pipe4.plugFlowPipe.vol_a.dynBal.medium: Temperature T = 262.35 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "AixLib.Media.Water"." Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 2 warnings info: 3 errors