(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_Systems_ModularAHU_Examples_DemandControlledAHU_OMSimulator-cs-euler_fmu --startTime=5.9616e+06 --stopTime=6.5664e+06 --stepSize=120 --mode=cs --timeout=240 --tolerance=1e-05 ../AixLib_AixLib_Systems_ModularAHU_Examples_DemandControlledAHU_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : AixLib.Systems.ModularAHU.Examples.DemandControlledAHU (co-simulation) - fmiVersion: 2.0 - startTime : 5961600.000000 - stopTime : 6566400.000000 - tolerance : 1e-05 - stepSize : 120 LOG_STDOUT | info | ... loading "internalGains" from "/tmp/tmptuyt9rc0/DemandControlledAHU-clsi2g41/temp/0001_DemandControlledAHU/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/LowOrder_ExampleData/SIA2024_SingleOffice_week.txt" warning: [fmi2Warning] DemandControlledAHU/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391: The following assertion has been violated during initialization at time 5961600.000000 ((genericAHU.fanSup.nominalValuesDefineDefaultPressureCurve), genericAHU.fanSup.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in DemandControlledAHU.genericAHU.fanSup: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." warning: [fmi2Warning] DemandControlledAHU/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391: The following assertion has been violated during initialization at time 5961600.000000 ((genericAHU.fanRet.nominalValuesDefineDefaultPressureCurve), genericAHU.fanRet.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in DemandControlledAHU.genericAHU.fanRet: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." info: Result file: AixLib_AixLib_Systems_ModularAHU_Examples_DemandControlledAHU_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter DemandControlledAHU.genericAHU.cooler.hydraulicModule.PumpInterface.physics.maxMinTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.genericAHU.cooler.hydraulicModule.PumpInterface.physics.maxMinTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.genericAHU.cooler.hydraulicModule.PumpInterface.physics.maxMinTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.cooler.hydraulicModule.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.cooler.hydraulicModule.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.cooler.hydraulicModule.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.cooler.hydraulicModule.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.cooler.hydraulicModule.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.cooler.hydraulicModule.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.cooler.hydraulicModule.pipeModel will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.genericAHU.cooler.hydraulicModuleIcon will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.genericAHU.heater.hydraulicModule.PumpInterface.physics.maxMinTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.genericAHU.heater.hydraulicModule.PumpInterface.physics.maxMinTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.genericAHU.heater.hydraulicModule.PumpInterface.physics.maxMinTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.heater.hydraulicModule.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.heater.hydraulicModule.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.heater.hydraulicModule.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.heater.hydraulicModule.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.heater.hydraulicModule.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.heater.hydraulicModule.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.heater.hydraulicModule.pipeModel will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.genericAHU.heater.hydraulicModuleIcon will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.genericAHU.preheater.hydraulicModule.PumpInterface.physics.maxMinTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.genericAHU.preheater.hydraulicModule.PumpInterface.physics.maxMinTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.genericAHU.preheater.hydraulicModule.PumpInterface.physics.maxMinTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.preheater.hydraulicModule.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.preheater.hydraulicModule.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.preheater.hydraulicModule.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.preheater.hydraulicModule.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.preheater.hydraulicModule.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.preheater.hydraulicModule.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable DemandControlledAHU.genericAHU.preheater.hydraulicModule.pipeModel will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.genericAHU.preheater.hydraulicModuleIcon will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.internalGains.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.internalGains.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.internalGains.tableName will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.thermalZone.zoneParam.TSoiFil will not be stored in the result file, because the signal type is not supported info: Parameter DemandControlledAHU.weaDat.filNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.ModularAHU.Examples.DemandControlledAHU/622.fmutmp/sources/AixLib_AixLib_Systems_ModularAHU_Examples_DemandControlledAHU_functions.c:2494: Invalid root: (-0.128289)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.ModularAHU.Examples.DemandControlledAHU/622.fmutmp/sources/AixLib_AixLib_Systems_ModularAHU_Examples_DemandControlledAHU_functions.c:2504: Invalid root: (-0.128289)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.ModularAHU.Examples.DemandControlledAHU/622.fmutmp/sources/AixLib_AixLib_Systems_ModularAHU_Examples_DemandControlledAHU_functions.c:2543: Invalid root: (-0.128289)^(-1.25) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.ModularAHU.Examples.DemandControlledAHU/622.fmutmp/sources/AixLib_AixLib_Systems_ModularAHU_Examples_DemandControlledAHU_functions.c:2553: Invalid root: (-0.128289)^(-1.25) error: [stepUntil] fmi2_doStep failed for FMU "DemandControlledAHU.root.DemandControlledAHU" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 2 warnings info: 1 errors