(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_Systems_HydraulicModules_Examples_Pump_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=800 --stepSize=5 --mode=cs --timeout=240 --tolerance=1e-06 ../AixLib_AixLib_Systems_HydraulicModules_Examples_Pump_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : AixLib.Systems.HydraulicModules.Examples.Pump (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 800.000000 - tolerance : 1e-06 - stepSize : 5 warning: [fmi2Warning] Pump/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Euler/powerWithDerivative.mo:7: The following assertion has been violated at time 0.000000 ((Unmixed.PumpInterface.pump.eff.powEu_internal.P[1] >= 0.0), Unmixed.PumpInterface.pump.eff.powEu_internal.P[1]=-0.1403010276548997) --> "Variable violating min constraint: 0.0 <= Unmixed.PumpInterface.pump.eff.powEu_internal.P[1], has value: -0.140301" warning: [fmi2Warning] Pump/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/Characteristics/powerParameters.mo:6: The following assertion has been violated at time 0.000000 ((Unmixed.PumpInterface.pump.eff.powEu.P[1] >= 0.0), Unmixed.PumpInterface.pump.eff.powEu.P[1]=-0.1403010276548997) --> "Variable violating min constraint: 0.0 <= Unmixed.PumpInterface.pump.eff.powEu.P[1], has value: -0.140301" warning: [fmi2Warning] Pump/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:100: The following assertion has been violated at time 0.000000 ((Unmixed.PumpInterface.pump.eta >= 0.0), Unmixed.PumpInterface.pump.eta=-9.642470631782173e-30) --> "Variable violating min constraint: 0.0 <= Unmixed.PumpInterface.pump.eta, has value: -9.64247e-30" warning: [fmi2Warning] Pump/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PowerInterface.mo:46: The following assertion has been violated at time 0.000000 ((Unmixed.PumpInterface.pump.heaDis.etaHyd >= 0.0), Unmixed.PumpInterface.pump.heaDis.etaHyd=-8.08611399339406e-27) --> "Variable violating min constraint: 0.0 <= Unmixed.PumpInterface.pump.heaDis.etaHyd, has value: -8.08611e-27" warning: [fmi2Warning] Pump/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311: The following assertion has been violated at time 0.000000 ((Unmixed.PumpInterface.pump.eff.yMot >= 0.0), Unmixed.PumpInterface.pump.eff.yMot=-1.075604987157968e-31) --> "Variable violating min constraint: 0.0 <= Unmixed.PumpInterface.pump.eff.yMot, has value: -1.0756e-31" info: Result file: AixLib_AixLib_Systems_HydraulicModules_Examples_Pump_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable Pump.Unmixed.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable Pump.Unmixed.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable Pump.Unmixed.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable Pump.Unmixed.pipeModel will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] Pump/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Media/Water.mo:66: The following assertion has been violated at time 6.966195 ((noEvent(Unmixed.pipe1.plugFlowPipe.vol_a.dynBal.medium.T <= 403.15)), Unmixed.pipe1.plugFlowPipe.vol_a.dynBal.medium.T=421.2701085308948) --> "In Pump.Unmixed.pipe1.plugFlowPipe.vol_a.dynBal.medium: Temperature T = 421.27 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "AixLib.Media.Water"." error: [fmi2logger] [fmi2Error] Pump/logFmi2Call: fmi2DoStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "Pump.root.Pump" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Media/Water.mo:66:5-67:119:writable] | | | | The following assertion has been violated at time 6.966195 | | | | ((noEvent(Unmixed.pipe1.plugFlowPipe.vol_a.dynBal.medium.T <= 403.15)), Unmixed.pipe1.plugFlowPipe.vol_a.dynBal.medium.T=421.2701085310315) --> "In Pump.Unmixed.pipe1.plugFlowPipe.vol_a.dynBal.medium: Temperature T = 421.27 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "AixLib.Media.Water"." Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 5 warnings info: 3 errors