(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_DynamicValidation_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=7200 --stepSize=2 --mode=cs --timeout=240 --tolerance=1e-06 ../AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_DynamicValidation_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.DynamicValidation (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 7200.000000 - tolerance : 1e-06 - stepSize : 2 LOG_STDOUT | info | ... loading "Boundary" from "/tmp/tmpdrf9rgph/DynamicValidation-f05hmfg8/temp/0001_DynamicValidation/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/DynamicValidationEta.txt" LOG_STDOUT | info | ... loading "Boundary" from "/tmp/tmpdrf9rgph/DynamicValidation-f05hmfg8/temp/0001_DynamicValidation/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/DynamicValidationOda.txt" LOG_STDOUT | info | ... loading "Result" from "/tmp/tmpdrf9rgph/DynamicValidation-f05hmfg8/temp/0001_DynamicValidation/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/DynamicValidationResult.txt" warning: [fmi2Warning] DynamicValidation/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391: The following assertion has been violated during initialization at time 0.000000 ((fan.nominalValuesDefineDefaultPressureCurve), fan.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in DynamicValidation.fan: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." warning: [fmi2Warning] DynamicValidation/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391: The following assertion has been violated during initialization at time 0.000000 ((fan1.nominalValuesDefineDefaultPressureCurve), fan1.nominalValuesDefineDefaultPressureCurve=false) --> "*** Warning in DynamicValidation.fan1: Mover is flow or pressure controlled and uses default pressure curve. This leads to an approximate power consumption. Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." info: Result file: AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_DynamicValidation_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter DynamicValidation.Results.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DynamicValidation.Results.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DynamicValidation.Results.tableName will not be stored in the result file, because the signal type is not supported info: Parameter DynamicValidation.bondaryEta.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DynamicValidation.bondaryEta.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DynamicValidation.bondaryEta.tableName will not be stored in the result file, because the signal type is not supported info: Parameter DynamicValidation.bondaryOda.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DynamicValidation.bondaryOda.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DynamicValidation.bondaryOda.tableName will not be stored in the result file, because the signal type is not supported info: Variable DynamicValidation.senMasFraEha.substanceName will not be stored in the result file, because the signal type is not supported info: Variable DynamicValidation.senMasFraEta.substanceName will not be stored in the result file, because the signal type is not supported info: Variable DynamicValidation.senMasFraOda.substanceName will not be stored in the result file, because the signal type is not supported info: Variable DynamicValidation.senMasFraSup.substanceName will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] DynamicValidation/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Utilities/Math/Functions/linearInterpolation.mo:13: Independent variable must be greater than or equal to 0.3 error: [stepUntil] fmi2_doStep failed for FMU "DynamicValidation.root.DynamicValidation" error: [fmi2logger] [fmi2Error] DynamicValidation/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Utilities/Math/Functions/linearInterpolation.mo:13: Independent variable must be greater than or equal to 0.3 error: [fmi2logger] [fmi2Error] DynamicValidation/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable souOda.verifyInputs Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 2 warnings info: 5 errors