(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_TransiEnt_TransiEnt_Grid_Heat_HeatGridControl_Check_Test_HeatDemandPrediction_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=3.16224e+07 --stepSize=900 --mode=cs --timeout=240 --tolerance=1e-08 ../TransiEnt_TransiEnt_Grid_Heat_HeatGridControl_Check_Test_HeatDemandPrediction_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-08 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : TransiEnt.Grid.Heat.HeatGridControl.Check.Test_HeatDemandPrediction (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 31622400.000000 - tolerance : 1e-08 - stepSize : 900 LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/\heat\TypicalHeatLoad_DHN_Normalized.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/\heat\TypicalHeatLoad_DHN_Normalized.txt LOG_ASSERT | debug | Not possible to open file "/tmp/tmp3rob9mz5/Test_HeatDemandPrediction-jxev4qfj/temp/0001_Test_HeatDemandPrediction/resources//home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/\heat\TypicalHeatLoad_DHN_Normalized.txt": No such file or directory error: [fmi2logger] [fmi2Error] Test_HeatDemandPrediction/logFmi2Call: fmi2ExitInitializationMode: failed error: [initialize] fmi2_exitInitializationMode failed for FMU "Test_HeatDemandPrediction.root.Test_HeatDemandPrediction" error: [fmi2logger] [fmi2Error] Test_HeatDemandPrediction/logStatusError: fmi2Terminate: Illegal co-simulation call sequence. fmi2Terminate is not allowed in model_state_error state. error: [terminate] Termination of system "Test_HeatDemandPrediction" failed error: [terminate] Termination of system "Test_HeatDemandPrediction.root" failed error: [initialize] Initialization of system "Test_HeatDemandPrediction.root" failed Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 175, in _runFMU fmu.initialize() ~~~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 887, in initialize raise RuntimeError(f"Failed to initialize model: {status}") RuntimeError: Failed to initialize model: Status.error error: [fmi2logger] [fmi2Error] Test_HeatDemandPrediction/logStatusError: fmi2Terminate: Illegal co-simulation call sequence. fmi2Terminate is not allowed in model_state_error state. error: [terminate] Termination of system "Test_HeatDemandPrediction" failed error: [terminate] Termination of system "Test_HeatDemandPrediction.root" failed info: 0 warnings info: 9 errors