(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_TransiEnt_TransiEnt_Consumer_Heat_Check_TestConsumer_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=6.048e+06 --stepSize=2419.2 --mode=cs --timeout=240 --tolerance=1e-06 ../TransiEnt_TransiEnt_Consumer_Heat_Check_TestConsumer_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : TransiEnt.Consumer.Heat.Check.TestConsumer (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 6048000.000000 - tolerance : 1e-06 - stepSize : 2419.2 LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//heat/HeatLoad.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/heat/HeatLoad.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/heat/HeatLoad.txt" LOG_STDOUT | warning | The table dimensions of matrix "default(8759,2)" from file "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/heat/HeatLoad.txt" do not match the actual table size (line 8762). info: Result file: TransiEnt_TransiEnt_Consumer_Heat_Check_TestConsumer_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter TestConsumer.consumer_LowTemperatureDHN.DHWfileName will not be stored in the result file, because the signal type is not supported info: Parameter TestConsumer.consumer_LowTemperatureDHN.DHWtableName will not be stored in the result file, because the signal type is not supported info: Parameter TestConsumer.consumer_SLP.combiTimeTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter TestConsumer.consumer_SLP.combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter TestConsumer.consumer_SLP.relativepath will not be stored in the result file, because the signal type is not supported