(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Processes.Tests.Pump_dp_tau_centrifugal_Characteristics_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Pump_dp_tau_centrifugal_Characteristics_OMSimulator-cs-cvode_fmu --startTime=-1 --stopTime=1.55 --stepSize=0.01 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Pump_dp_tau_centrifugal_Characteristics_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Processes.Tests.Pump_dp_tau_centrifugal_Characteristics (co-simulation) - fmiVersion: 2.0 - startTime : -1.000000 - stopTime : 1.550000 - tolerance : 1e-06 - stepSize : 0.01 warning: [fmi2Warning] Pump_dp_tau_centrifugal_Characteristics/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time -1.000000 ((legacyPump.p_min >= 611.657 and legacyPump.p_min <= 1e8), legacyPump.p_min=100) --> "Variable violating min/max constraint: 611.657 <= legacyPump.p_min <= 1e8, has value: 100" warning: [fmi2Warning] Pump_dp_tau_centrifugal_Characteristics/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time -1.000000 ((correctedPump.p_min >= 611.657 and correctedPump.p_min <= 1e8), correctedPump.p_min=100) --> "Variable violating min/max constraint: 611.657 <= correctedPump.p_min <= 1e8, has value: 100" info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Processes.Tests.Pump_dp_tau_centrifugal_Characteristics_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable Pump_dp_tau_centrifugal_Characteristics.correctedPump.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.flowSensor.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.flowSensor1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.legacyPump.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.sink.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.sink.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.sink.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.sink1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.sink1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.sink1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source1.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source1.instanceName will not be stored in the result file, because the signal type is not supported info: 2 warnings info: 0 errors