(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise5TurboChargedDieselEngine.Flow_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise5TurboChargedDieselEngine_Flow_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise5TurboChargedDieselEngine_Flow_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise5TurboChargedDieselEngine.Flow (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1.000000 - tolerance : 1e-06 - stepSize : 0.01 warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Examples/TUMExercisesThermodynamicCycles/Exercise5TurboChargedDieselEngine/BaseModel.mo:16: The following assertion has been violated at time 0.000000 ((T5 >= 273.15 and T5 <= 373.15), T5=1700) --> "Variable violating min/max constraint: 273.15 <= T5 <= 373.15, has value: 1700" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/Isobaric.mo:22: The following assertion has been violated at time 0.000000 ((combustion.T_out_fixed >= 273.15 and combustion.T_out_fixed <= 373.15), combustion.T_out_fixed=1700) --> "Variable violating min/max constraint: 273.15 <= combustion.T_out_fixed <= 373.15, has value: 1700" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/Isobaric.mo:69: The following assertion has been violated at time 0.000000 ((combustion.T_out >= 273.15 and combustion.T_out <= 373.15), combustion.T_out=1700) --> "Variable violating min/max constraint: 273.15 <= combustion.T_out <= 373.15, has value: 1700" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463: The following assertion has been violated at time 0.000000 ((engineCompression.outlet.state.T >= 273.15 and engineCompression.outlet.state.T <= 373.15), engineCompression.outlet.state.T=997.2297023639326) --> "Variable violating min/max constraint: 273.15 <= engineCompression.outlet.state.T <= 373.15, has value: 997.23" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/PolytropicPerfectGas.mo:105: The following assertion has been violated at time 0.000000 ((engineCompression.T_out >= 273.15 and engineCompression.T_out <= 373.15), engineCompression.T_out=997.2297023639326) --> "Variable violating min/max constraint: 273.15 <= engineCompression.T_out <= 373.15, has value: 997.23" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463: The following assertion has been violated at time 0.000000 ((combustion.outlet.state.T >= 273.15 and combustion.outlet.state.T <= 373.15), combustion.outlet.state.T=1700) --> "Variable violating min/max constraint: 273.15 <= combustion.outlet.state.T <= 373.15, has value: 1700" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/Isobaric.mo:67: The following assertion has been violated at time 0.000000 ((combustion.T_in >= 273.15 and combustion.T_in <= 373.15), combustion.T_in=997.2297023639326) --> "Variable violating min/max constraint: 273.15 <= combustion.T_in <= 373.15, has value: 997.23" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463: The following assertion has been violated at time 0.000000 ((engineExpansion.outlet.state.T >= 273.15 and engineExpansion.outlet.state.T <= 373.15), engineExpansion.outlet.state.T=632.9026320234125) --> "Variable violating min/max constraint: 273.15 <= engineExpansion.outlet.state.T <= 373.15, has value: 632.903" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/PolytropicPerfectGas.mo:92: The following assertion has been violated at time 0.000000 ((engineExpansion.T_in >= 273.15 and engineExpansion.T_in <= 373.15), engineExpansion.T_in=1700) --> "Variable violating min/max constraint: 273.15 <= engineExpansion.T_in <= 373.15, has value: 1700" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/PolytropicPerfectGas.mo:105: The following assertion has been violated at time 0.000000 ((engineExpansion.T_out >= 273.15 and engineExpansion.T_out <= 373.15), engineExpansion.T_out=632.9026320234124) --> "Variable violating min/max constraint: 273.15 <= engineExpansion.T_out <= 373.15, has value: 632.903" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463: The following assertion has been violated at time 0.000000 ((turbine.outlet.state.T >= 273.15 and turbine.outlet.state.T <= 373.15), turbine.outlet.state.T=616.873512717046) --> "Variable violating min/max constraint: 273.15 <= turbine.outlet.state.T <= 373.15, has value: 616.874" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463: The following assertion has been violated at time 0.000000 ((turbine.adiabaticModel.state_in.T >= 273.15 and turbine.adiabaticModel.state_in.T <= 373.15), turbine.adiabaticModel.state_in.T=632.9026320234125) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.state_in.T <= 373.15, has value: 632.903" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:25: The following assertion has been violated at time 0.000000 ((turbine.adiabaticModel.T_in >= 273.15 and turbine.adiabaticModel.T_in <= 373.15), turbine.adiabaticModel.T_in=632.9026320234125) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.T_in <= 373.15, has value: 632.903" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:27: The following assertion has been violated at time 0.000000 ((turbine.adiabaticModel.T_out_is >= 273.15 and turbine.adiabaticModel.T_out_is <= 373.15), turbine.adiabaticModel.T_out_is=616.873512717046) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.T_out_is <= 373.15, has value: 616.874" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463: The following assertion has been violated at time 0.000000 ((turbine.adiabaticModel.state_out.T >= 273.15 and turbine.adiabaticModel.state_out.T <= 373.15), turbine.adiabaticModel.state_out.T=616.873512717046) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.state_out.T <= 373.15, has value: 616.874" warning: [fmi2Warning] Flow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/AdiabaticThermodynamicModels/PerfectGas.mo:20: The following assertion has been violated at time 0.000000 ((turbine.adiabaticModel.T_out >= 273.15 and turbine.adiabaticModel.T_out <= 373.15), turbine.adiabaticModel.T_out=616.873512717046) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.T_out <= 373.15, has value: 616.874" info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise5TurboChargedDieselEngine.Flow_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable Flow.combustion.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Flow.compressor.adiabaticModel.name will not be stored in the result file, because the signal type is not supported info: Variable Flow.compressor.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Flow.cooler.instanceName will not be stored in the result file, because the signal type is not supported info: Parameter Flow.efficiency.description will not be stored in the result file, because the signal type is not supported info: Variable Flow.engineCompression.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Flow.engineExpansion.instanceName will not be stored in the result file, because the signal type is not supported info: Parameter Flow.massFlowRate1.description will not be stored in the result file, because the signal type is not supported info: Parameter Flow.power.description will not be stored in the result file, because the signal type is not supported info: Variable Flow.sink.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Flow.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Flow.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Flow.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Flow.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Flow.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Flow.turbine.adiabaticModel.name will not be stored in the result file, because the signal type is not supported info: Variable Flow.turbine.instanceName will not be stored in the result file, because the signal type is not supported info: Parameter Flow.turbineWork.description will not be stored in the result file, because the signal type is not supported info: Variable Flow.valve.instanceName will not be stored in the result file, because the signal type is not supported info: 16 warnings info: 0 errors