(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise3OttoEngine.PolytropicFlow_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_PolytropicFlow_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise3OttoEngine_PolytropicFlow_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise3OttoEngine.PolytropicFlow (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1.000000 - tolerance : 1e-06 - stepSize : 0.01 warning: [fmi2Warning] PolytropicFlow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Examples/TUMExercisesThermodynamicCycles/Exercise3OttoEngine/BaseModel.mo:10: The following assertion has been violated at time 0.000000 ((T3 >= 273.15 and T3 <= 373.15), T3=2200) --> "Variable violating min/max constraint: 273.15 <= T3 <= 373.15, has value: 2200" warning: [fmi2Warning] PolytropicFlow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/Isochoric.mo:21: The following assertion has been violated at time 0.000000 ((combustion.T_out_fixed >= 273.15 and combustion.T_out_fixed <= 373.15), combustion.T_out_fixed=2200) --> "Variable violating min/max constraint: 273.15 <= combustion.T_out_fixed <= 373.15, has value: 2200" warning: [fmi2Warning] PolytropicFlow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/Isochoric.mo:62: The following assertion has been violated at time 0.000000 ((combustion.T_out >= 273.15 and combustion.T_out <= 373.15), combustion.T_out=2200) --> "Variable violating min/max constraint: 273.15 <= combustion.T_out <= 373.15, has value: 2200" warning: [fmi2Warning] PolytropicFlow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463: The following assertion has been violated at time 0.000000 ((compression.outlet.state.T >= 273.15 and compression.outlet.state.T <= 373.15), compression.outlet.state.T=752.8206019761617) --> "Variable violating min/max constraint: 273.15 <= compression.outlet.state.T <= 373.15, has value: 752.821" warning: [fmi2Warning] PolytropicFlow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/PolytropicPerfectGas.mo:105: The following assertion has been violated at time 0.000000 ((compression.T_out >= 273.15 and compression.T_out <= 373.15), compression.T_out=752.8206019761617) --> "Variable violating min/max constraint: 273.15 <= compression.T_out <= 373.15, has value: 752.821" warning: [fmi2Warning] PolytropicFlow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463: The following assertion has been violated at time 0.000000 ((combustion.outlet.state.T >= 273.15 and combustion.outlet.state.T <= 373.15), combustion.outlet.state.T=2200) --> "Variable violating min/max constraint: 273.15 <= combustion.outlet.state.T <= 373.15, has value: 2200" warning: [fmi2Warning] PolytropicFlow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/Isochoric.mo:60: The following assertion has been violated at time 0.000000 ((combustion.T_in >= 273.15 and combustion.T_in <= 373.15), combustion.T_in=752.8206019761617) --> "Variable violating min/max constraint: 273.15 <= combustion.T_in <= 373.15, has value: 752.821" warning: [fmi2Warning] PolytropicFlow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463: The following assertion has been violated at time 0.000000 ((expansion.outlet.state.T >= 273.15 and expansion.outlet.state.T <= 373.15), expansion.outlet.state.T=876.702893448311) --> "Variable violating min/max constraint: 273.15 <= expansion.outlet.state.T <= 373.15, has value: 876.703" warning: [fmi2Warning] PolytropicFlow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/PolytropicPerfectGas.mo:92: The following assertion has been violated at time 0.000000 ((expansion.T_in >= 273.15 and expansion.T_in <= 373.15), expansion.T_in=2200) --> "Variable violating min/max constraint: 273.15 <= expansion.T_in <= 373.15, has value: 2200" warning: [fmi2Warning] PolytropicFlow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/PolytropicPerfectGas.mo:105: The following assertion has been violated at time 0.000000 ((expansion.T_out >= 273.15 and expansion.T_out <= 373.15), expansion.T_out=876.7028934483109) --> "Variable violating min/max constraint: 273.15 <= expansion.T_out <= 373.15, has value: 876.703" warning: [fmi2Warning] PolytropicFlow/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/Isochoric.mo:60: The following assertion has been violated at time 0.000000 ((gasExchange.T_in >= 273.15 and gasExchange.T_in <= 373.15), gasExchange.T_in=876.702893448311) --> "Variable violating min/max constraint: 273.15 <= gasExchange.T_in <= 373.15, has value: 876.703" info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise3OttoEngine.PolytropicFlow_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable PolytropicFlow.combustion.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PolytropicFlow.combustion.name will not be stored in the result file, because the signal type is not supported info: Variable PolytropicFlow.compression.instanceName will not be stored in the result file, because the signal type is not supported info: Parameter PolytropicFlow.efficiency.description will not be stored in the result file, because the signal type is not supported info: Variable PolytropicFlow.expansion.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PolytropicFlow.gasExchange.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PolytropicFlow.gasExchange.name will not be stored in the result file, because the signal type is not supported info: Variable PolytropicFlow.loopBreaker.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PolytropicFlow.loopBreaker.name will not be stored in the result file, because the signal type is not supported info: Parameter PolytropicFlow.maximumPressure.description will not be stored in the result file, because the signal type is not supported info: Parameter PolytropicFlow.netWork.description will not be stored in the result file, because the signal type is not supported info: 11 warnings info: 0 errors