(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.CombinedCycle.Step1Simple_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_CombinedCycle_Step1Simple_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_CombinedCycle_Step1Simple_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Idealized.Examples.CombinedCycle.Step1Simple (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1.000000 - tolerance : 1e-06 - stepSize : 0.01 warning: [fmi2Warning] Step1Simple/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((condenser.p_min >= 611.657 and condenser.p_min <= 1e8), condenser.p_min=100) --> "Variable violating min/max constraint: 611.657 <= condenser.p_min <= 1e8, has value: 100" warning: [fmi2Warning] Step1Simple/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((heatExchangerWaterSide.p_min >= 611.657 and heatExchangerWaterSide.p_min <= 1e8), heatExchangerWaterSide.p_min=100) --> "Variable violating min/max constraint: 611.657 <= heatExchangerWaterSide.p_min <= 1e8, has value: 100" warning: [fmi2Warning] Step1Simple/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((turbineCR.p_min >= 611.657 and turbineCR.p_min <= 1e8), turbineCR.p_min=100) --> "Variable violating min/max constraint: 611.657 <= turbineCR.p_min <= 1e8, has value: 100" warning: [fmi2Warning] Step1Simple/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((pump.p_min >= 611.657 and pump.p_min <= 1e8), pump.p_min=100) --> "Variable violating min/max constraint: 611.657 <= pump.p_min <= 1e8, has value: 100" info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.CombinedCycle.Step1Simple_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable Step1Simple.airSink.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.airSource.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.airSource.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.airSource.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.airSource.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.airSource.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.combustion.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.compressor.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.condenser.instanceName will not be stored in the result file, because the signal type is not supported info: Parameter Step1Simple.efficiency.description will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.heatExchangerAirSide.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.heatExchangerWaterSide.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.loopBreaker.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.loopBreaker.name will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.pump.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.turbineCR.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step1Simple.turbineJB.instanceName will not be stored in the result file, because the signal type is not supported info: 4 warnings info: 0 errors