(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.FlowControl.Tests.PCV_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_PCV_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=1 --stepSize=0.0004 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_FlowControl_Tests_PCV_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : ThermofluidStream.FlowControl.Tests.PCV (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1.000000 - tolerance : 1e-06 - stepSize : 0.0004 info: Result file: ../ThermofluidStream_dev_ThermofluidStream.FlowControl.Tests.PCV_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable PCV.flowResValve1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.flowResValve2.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.flowResValve3.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.flowResValve4.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.flowResValve5.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.pCValve1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.pCValve2.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.pCValve3.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.pCValve4.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.pCValve5.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.sinkValve1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sinkValve1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sinkValve1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.sinkValve2.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sinkValve2.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sinkValve2.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.sinkValve5.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sinkValve5.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sinkValve5.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve1.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve2.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve2.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve2.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve2.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve2.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve5.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve5.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve5.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve5.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable PCV.sourceValve5.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.volumeFlex1Valve3.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.volumeFlex1Valve4.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.volumeFlex2Valve3.instanceName will not be stored in the result file, because the signal type is not supported info: Variable PCV.volumeFlex2Valve4.instanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Boundaries/Internal/PartialVolume.mo:114:3-114:138:writable] | | | | The following assertion has been violated at time 0.196000 | | | | ((flowResValve4.inlet.m_flow > volumeFlex2Valve4.m_flow_assert), flowResValve4.inlet.m_flow=-0.01035737279359108, volumeFlex2Valve4.m_flow_assert=-0.01) --> "In "PCV.volumeFlex2Valve4": Negative mass flow rate at Volume inlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Boundaries/Internal/PartialVolume.mo:115:3-115:141:writable] | | | | The following assertion has been violated at time 0.196000 | | | | ((flowResValve4.inlet.m_flow > volumeFlex1Valve4.m_flow_assert), flowResValve4.inlet.m_flow=-0.01035737279359108, volumeFlex1Valve4.m_flow_assert=-0.01) --> "In "PCV.volumeFlex1Valve4": Positive mass flow rate at Volume outlet"