(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Boundaries.Tests.TankOverfilling_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Boundaries_Tests_TankOverfilling_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=1000 --stepSize=0.4 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Boundaries_Tests_TankOverfilling_OMSimulator-cs-cvode.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Boundaries.Tests.TankOverfilling (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1000.000000 - tolerance : 1e-06 - stepSize : 0.4 info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Boundaries.Tests.TankOverfilling_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable TankOverfilling.acceleration.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.checkValve.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.flowResistance.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.flowResistance2.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.flowResistance3.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.sink.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.sink.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.sink.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.source1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.source1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.source1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.source1.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.source1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TankOverfilling.tank1.instanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Boundaries/TankCuboid.mo:47:3-47:136:writable] | | | | The following assertion has been violated at time 17.200000 | | | | ((tank1.V_liquid <= tank1.V_ref), tank1.V_liquid=1.000021692780416, tank1.V_ref=1) --> "In "TankOverfilling.tank1": Trying to fit more liquid into tank than it holds" LOG_ASSERT | debug | Solving non-linear system 159 failed at time=17.3516555179363. | | | | For more information please use -lv LOG_NLS.