(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_HeatExchanger_DynamicWaterHeater_ZeroFlow_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=3000 --stepSize=1.2 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermoSysPro_ThermoSysPro_Fluid_Examples_Book_SimpleExamples_HeatExchanger_DynamicWaterHeater_ZeroFlow_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using sparse linear solver SUNLinSol_KLU. LOG_SOLVER | info | CVODE Use sparse Jacobian method coloredNumerical LOG_SOLVER | info | CVODE uses internal root finding method YES LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm ON info: *** FMU Simulation Info *** - model : ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 3000.000000 - tolerance : 1e-06 - stepSize : 1.2 LOG_STDOUT | warning | While solving non-linear system an assertion failed during initialization. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_STDOUT | warning | While solving non-linear system an assertion failed during initialization. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_ASSERT | debug | Solving non-linear system 1519 failed at time=0. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] ZeroFlow/logFmi2Call: fmi2ExitInitializationMode: failed error: [initialize] fmi2_exitInitializationMode failed for FMU "ZeroFlow.root.ZeroFlow" error: [fmi2logger] [fmi2Error] ZeroFlow/logStatusError: fmi2Terminate: Illegal co-simulation call sequence. fmi2Terminate is not allowed in model_state_error state. error: [terminate] Termination of system "ZeroFlow" failed error: [terminate] Termination of system "ZeroFlow.root" failed error: [initialize] Initialization of system "ZeroFlow.root" failed Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 175, in _runFMU fmu.initialize() ~~~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 887, in initialize raise RuntimeError(f"Failed to initialize model: {status}") RuntimeError: Failed to initialize model: Status.error error: [fmi2logger] [fmi2Error] ZeroFlow/logStatusError: fmi2Terminate: Illegal co-simulation call sequence. fmi2Terminate is not allowed in model_state_error state. error: [terminate] Termination of system "ZeroFlow" failed error: [terminate] Termination of system "ZeroFlow.root" failed info: 0 warnings info: 9 errors